ArticleMedical physics2013
Monte Carlo study of the effects of system geometry and antiscatter grids on cone-beam CT scatter distributions.
Article in Medical physics, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 49 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
49 citing papers in PubMed.
- Scatter and beam hardening effect corrections in pelvic region cone beam CT images using a convolutional neural network.Radiological physics and technology · 2025Article
- Evaluation of a compact cone beam CT concept with high image fidelity for point-of-care brain imaging.Scientific reports · 2024Article
- Vessel-targeted compensation of deformable motion in interventional cone-beam CT.Medical image analysis · 2024Article
- Joint Material Decomposition and Scatter Estimation for Spectral CT.Conference proceedings. International Conference on Image Formation in X-Ray Computed Tomography · 2024Article
- Deformable motion compensation in interventional cone-beam CT with a context-aware learned autofocus metric.Medical physics · 2024Article
- 3D Digital Modeling of Dental Casts from Their 3D CT Images with Scatter and Beam-Hardening Correction.Sensors (Basel, Switzerland) · 2024Article
- A simulation study to evaluate the effect of 2D antiscatter grid primary transmission on flat panel detector based CBCT image quality.Biomedical physics & engineering express · 2023Article
- Combining physics-based models with deep learning image synthesis and uncertainty in intraoperative cone-beam CT of the brain.Medical physics · 2023Article
- Multi-Stage Adaptive Spline Autofocus (MASA) with a Learned Metric for Deformable Motion Compensation in Interventional Cone-Beam CT.Proceedings of SPIE--the International Society for Optical Engineering · 2023Article
- Model-based three-material decomposition in dual-energy CT using the volume conservation constraint.Physics in medicine and biology · 2022Article
- Investigation of the origin of scatter components transmitted through anti-scatter grids in X-ray Digital Imaging system using Monte Carlo Simulation.African health sciences · 2022Article
- Article
- Scatter-to-primary ratio in dentomaxillofacial cone-beam CT: effect of field of view and beam energy.Dento maxillo facial radiology · 2021Article
- Intraoperative cone-beam and slot-beam CT: 3D image quality and dose with a slot collimator on the O-arm imaging system.Medical physics · 2021Article
- Generating synthetic CT from low-dose cone-beam CT by using generative adversarial networks for adaptive radiotherapy.Radiation oncology (London, England) · 2021Article
- Comparison of Supervised and Unsupervised Approaches for the Generation of Synthetic CT from Cone-Beam CT.Diagnostics (Basel, Switzerland) · 2021Article
- Contextual loss based artifact removal method on CBCT image.Journal of applied clinical medical physics · 2020Article
- Artificial intelligence in radiotherapy: a technological review.Frontiers of medicine · 2020Review
- Cone-beam CT for imaging of the head/brain: Development and assessment of scanner prototype and reconstruction algorithms.Medical physics · 2020Article
- An Investigation of Slot-scanning for Mammography and Breast CT.Proceedings of SPIE--the International Society for Optical Engineering · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
purposeThe proliferation of cone-beam CT (CBCT) has created interest in performance optimization, with x-ray scatter identified among the main limitations to image quality. CBCT often contends with elevated scatter, but the wide variety of imaging geometry in different CBCT configurations suggests that not all configurations are affected to the same extent. Graphics processing unit (GPU) accelerated Monte Carlo (MC) simulations are employed over a range of imaging geometries to elucidate the factors governing scatter characteristics, efficacy of antiscatter grids, guide system design, and augment development of scatter correction.
methodsA MC x-ray simulator implemented on GPU was accelerated by inclusion of variance reduction techniques (interaction splitting, forced scattering, and forced detection) and extended to include x-ray spectra and analytical models of antiscatter grids and flat-panel detectors. The simulator was applied to small animal (SA), musculoskeletal (MSK) extremity, otolaryngology (Head), breast, interventional C-arm, and on-board (kilovoltage) linear accelerator (Linac) imaging, with an axis-to-detector distance (ADD) of 5, 12, 22, 32, 60, and 50 cm, respectively. Each configuration was modeled with and without an antiscatter grid and with (i) an elliptical cylinder varying 70-280 mm in major axis; and (ii) digital murine and anthropomorphic models. The effects of scatter were evaluated in terms of the angular distribution of scatter incident upon the detector, scatter-to-primary ratio (SPR), artifact magnitude, contrast, contrast-to-noise ratio (CNR), and visual assessment.
resultsVariance reduction yielded improvements in MC simulation efficiency ranging from ∼17-fold (for SA CBCT) to ∼35-fold (for Head and C-arm), with the most significant acceleration due to interaction splitting (∼6 to ∼10-fold increase in efficiency). The benefit of a more extended geometry was evident by virtue of a larger air gap-e.g., for a 16 cm diameter object, the SPR reduced from 1.5 for ADD = 12 cm (MSK geometry) to 1.1 for ADD = 22 cm (Head) and to 0.5 for ADD = 60 cm (C-arm). Grid efficiency was higher for configurations with shorter air gap due to a broader angular distribution of scattered photons-e.g., scatter rejection factor ∼0.8 for MSK geometry versus ∼0.65 for C-arm. Grids reduced cupping for all configurations but had limited improvement on scatter-induced streaks and resulted in a loss of CNR for the SA, Breast, and C-arm. Relative contribution of forward-directed scatter increased with a grid (e.g., Rayleigh scatter fraction increasing from ∼0.15 without a grid to ∼0.25 with a grid for the MSK configuration), resulting in scatter distributions with greater spatial variation (the form of which depended on grid orientation).
conclusionsA fast MC simulator combining GPU acceleration with variance reduction provided a systematic examination of a range of CBCT configurations in relation to scatter, highlighting the magnitude and spatial uniformity of individual scatter components, illustrating tradeoffs in CNR and artifacts and identifying the system geometries for which grids are more beneficial (e.g., MSK) from those in which an extended geometry is the better defense (e.g., C-arm head imaging). Compact geometries with an antiscatter grid challenge assumptions of slowly varying scatter distributions due to increased contribution of Rayleigh scatter.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.