Evidence map›Paper›PMID 23633347›Full record

SynthesisThe Cochrane database of systematic reviews2013

Initial arch wires for tooth alignment during orthodontic treatment with fixed appliances.

Fan Jian, Wenli Lai, Susan Furness, Grant T McIntyre, Declan T Millett, Joy Hickman, Yan Wang

Registry-linked trialOpen access · bronzeAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05391542 (Effectiveness of Tubular Coaxial Nickel-titanium and Copper Nickel-titanium Orthodontic Aligning Archwires), which is not on this map. Cited by 30 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
30citing papers in PubMed, 4 pooled it
3.2field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05391542 nacompletednot on this mapstarted 2022, after this paper: background citation

Effectiveness of Tubular Coaxial Nickel-titanium and Copper Nickel-titanium Orthodontic Aligning Archwires: A Randomized Clinical Trial

TypeinterventionalSponsorUniversity of BaghdadRan2022 to 2022Enrolled33ConditionsAligning ArchwiresArmsaligning archwires
3 · Its place in the literature

Who cites it

30 citing papers in PubMed, 4 syntheses or guidelines pooled it, 57 citations in OpenAlex.

  1. Initial arch wires used in orthodontic treatment with fixed appliances.The Cochrane database of systematic reviews · 2024
    Pooled it
  2. Initial arch wires used in orthodontic treatment with fixed appliances.The Cochrane database of systematic reviews · 2018
    Pooled it
  3. [Relationship between initial archwire materials and pain at the initial stage of orthodontic treatment: a systematic review and network Meta-analysis].Hua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology · 2018
    Pooled it
  4. Pooled it
  5. Trial
  6. Trial
  7. Trial
  8. Trial
  9. Trial
  10. Article
  11. Article
  12. Effect of Vitamin D on Orthodontic Tooth Movement.Journal of pharmacy & bioallied sciences · 2025
    Article
  13. Article
  14. Article
  15. Review
  16. Article
  17. Review
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 3 countries.

Fan JianDepartment of Orthodontics, State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University,Chengdu, China.
Wenli Lai
Susan Furness
Grant T McIntyre
Declan T Millett
Joy Hickman
Yan Wang
Sichuan University · CNGlan Clwyd Hospital · GBNHS Tayside · GBUniversity College Cork · IEUniversity of Manchester · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundInitial arch wires are the first arch wires to be inserted into the fixed appliance at the beginning of orthodontic treatment and are used mainly for the alignment of teeth by correcting crowding and rotations. With a number of different types of orthodontic arch wires available for initial tooth alignment, it is important to understand which wire is most efficient, as well as which wires cause the least amount of root resorption and pain during the initial aligning stage of treatment. This is an update of the review 'Initial arch wires for alignment of crooked teeth with fixed orthodontic braces' first published in the Cochrane Database of Systematic Reviews 2010, Issue 4.

objectivesTo assess the effects of initial arch wires for alignment of teeth with fixed orthodontic braces in relation to alignment speed, root resorption and pain intensity. SEARCH

methodsWe searched the following electronic databases: the Cochrane Oral Health Group's Trials Register (to 2 August 2012), CENTRAL (The Cochrane Library 2012, Issue 7), MEDLINE via OVID (1950 to 2 August 2012) and EMBASE via OVID (1980 to 2 August 2012). We also searched the reference lists of relevant articles. There was no restriction with regard to publication status or language of publication. We contacted all authors of included studies to identify additional studies. SELECTION CRITERIA: We included randomised controlled trials (RCTs) of initial arch wires to align teeth with fixed orthodontic braces. Only studies involving participants with upper and/or lower full arch fixed orthodontic appliances were included. DATA COLLECTION AND ANALYSIS: Two review authors were responsible for study selection, validity assessment and data extraction. All disagreements were resolved by discussion amongst the review team. Corresponding authors of included studies were contacted to obtain missing information. MAIN

resultsNine RCTs with 571 participants were included in this review. All trials were at high risk of bias and a number of methodological limitations were identified. All trials had at least one potentially confounding factor (such as bracket type, slot size, ligation method, extraction of teeth) which is likely to have influenced the outcome and was not controlled in the trial. None of the trials reported the important adverse outcome of root resorption.Three groups of comparisons were made.(1) Multistrand stainless steel initial arch wires compared to superelastic nickel titanium (NiTi) initial arch wires. There were four trials in this group, with different comparisons and outcomes reported at different times. No meta-analysis was possible. There is insufficient evidence from these trials to determine whether or not there is a difference in either rate of alignment or pain between stainless steel and NiTi initial arch wires.(2) Conventional (stabilised) NiTi initial arch wires compared to superelastic NiTi initial arch wires. There were two trials in this group, one reporting the outcome of alignment over 6 months and the other reporting pain over 1 week. There is insufficient evidence from these trials to determine whether or not there is any difference between conventional (stabilised) and superelastic NiTi initial arch wires with regard to either alignment or pain.(3) Single-strand superelastic NiTi initial arch wires compared to other NiTi (coaxial, copper NiTi (CuNiTi) or thermoelastic) initial arch wires. The three trials in this comparison each compared a different product against single-strand superelastic NiTi. There is very weak unreliable evidence, based on one very small study (n = 24) at high risk of bias, that coaxial superelastic NiTi may produce greater tooth movement over 12 weeks, but no information on associated pain or root resorption. This result should be interpreted with caution until further research evidence is available. There is insufficient evidence to determine whether or not there is a difference between either thermoelastic or CuNiTi and superelastic NiTi initial arch wires. AUTHORS'

conclusionsThere is no reliable evidence from the trials included in this review that any specific initial arch wire material is better or worse than another with regard to speed of alignment or pain. There is no evidence at all about the effect of initial arch wire materials on the important adverse effect of root resorption. Further well-designed and conducted, adequately-powered, RCTs are required to determine whether the performance of initial arch wire materials as demonstrated in the laboratory, makes a clinically important difference to the alignment of teeth in the initial stage of orthodontic treatment in patients.

Indexed as

Dental AlloysHumansOrthodontic BracketsOrthodontic WiresRandomized Controlled Trials as TopicRoot ResorptionToothacheTooth Movement TechniquesDental Alloys

Identifiers

PMID23633347
PMCPMC6465075
OpenAlexW1593127717

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.