Evidence map›Paper›PMID 23606429›Full record

ArticleContrast media & molecular imaging

EPR assessment of protein sites for incorporation of Gd(III) MRI contrast labels.

Jens O Lagerstedt, Jitka Petrlova, Silvia Hilt, Antonin Marek, Youngran Chung, Renuka Sriram, Madhu S Budamagunta, Jean F Desreux, David Thonon, Thomas Jue and 2 more

Abstract read
In one paragraph

Article in Contrast media & molecular imaging. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.8field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 4 institutions in 3 countries.

Jens O LagerstedtDepartment of Experimental Medical Science, Lund University, Lund, Sweden.
Jitka Petrlova
Silvia Hilt
Antonin Marek
Youngran Chung
Renuka Sriram
Madhu S Budamagunta
Jean F Desreux
David Thonon
Thomas Jue
Alex I Smirnov
John C Voss
University of California, Davis · USNorth Carolina State University · USUniversity of Liège · BELund University · SE

Funding

Training Program in Biomolecular TechnologyT32GM008799 · NIGMS · UNIVERSITY OF CALIFORNIA DAVIS · PI LEACH, J. KENT · 2002 to 2016
$2.4M
The structural basis of apoE4's role in Alzheimer's DiseaseR01AG029246 · NIA · UNIVERSITY OF CALIFORNIA AT DAVIS · PI VOSS, JOHN CARL · 2007 to 2011
$1.3M
NIA NIH HHS AG029246NIA NIH HHS R01 AG029246NIGMS NIH HHS T32 GM008799NIGMS NIH HHS T32-GM008799
6 · The paper itself

Abstract

We have engineered apolipoprotein A-I (apoA-I), a major protein constituent of high-density lipoprotein (HDL), to contain DOTA-chelated Gd(III) as an MRI contrast agent for the purpose of imaging reconstituted HDL (rHDL) biodistribution, metabolism and regulation in vivo. This protein contrast agent was obtained by attaching the thiol-reactive Gd[MTS-ADO3A] label at Cys residues replaced at four distinct positions (52, 55, 76 and 80) in apoA-I. MRI of infused mice previously showed that the Gd-labeled apoA-I migrates to both the liver and the kidney, the organs responsible for HDL catabolism; however, the contrast properties of apoA-I are superior when the ADO3A moiety is located at position 55, compared with the protein labeled at positions 52, 76 or 80. It is shown here that continuous wave X-band (9 GHz) electron paramagnetic resonance (EPR) spectroscopy is capable of detecting differences in the Gd(III) signal when comparing the labeled protein in the lipid-free with the rHDL state. Furthermore, the values of NMR relaxivity obtained for labeled variants in both the lipid-free and rHDL states correlate to the product of the X-band Gd(III) spectral width and the collision frequency between a nitroxide spin label and a polar relaxation agent. Consistent with its superior relaxivity measured by NMR, the rHDL-associated apoA-I containing the Gd[MTS-ADO3A] probe attached to position 55 displays favorable dynamic and water accessibility properties as determined by X-band EPR. While room temperature EPR requires >1 m m Gd(III)-labeled and only >10 µ m nitroxide-labeled protein to resolve the spectrum, the volume requirement is exceptionally low (~5 µl). Thus, X-band EPR provides a practical assessment for the suitability of imaging candidates containing the site-directed ADO3A contrast probe.

Indexed as

NanocapsulesBinding SitesContrast MediaDrug DesignElectron Spin Resonance SpectroscopyGadoliniumMagnetic Resonance ImagingProtein BindingProteinsReproducibility of ResultsSensitivity and SpecificityStaining and LabelingContrast MediaGadoliniumNanocapsulesProteins

Identifiers

PMID23606429
PMCPMC3633150
OpenAlexW2115336857

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.