Evidence map›Paper›PMID 23592078›Full record

ArticleJournal of the American Society for Mass Spectrometry2013

Multiplex mass spectrometric imaging with polarity switching for concurrent acquisition of positive and negative ion images.

Andrew R Korte, Young Jin Lee

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Article
  2. Article
  3. Single-Cell Metabolomics by Mass Spectrometry Imaging.Advances in experimental medicine and biology · 2021
    Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Article
  13. Review
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Andrew R KorteAmes Laboratory, US Department of Energy, Ames, IA 50011, USA.
Young Jin Lee

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We have recently developed a multiplex mass spectrometry imaging (MSI) method which incorporates high mass resolution imaging and MS/MS and MS(3) imaging of several compounds in a single data acquisition utilizing a hybrid linear ion trap-Orbitrap mass spectrometer (Perdian and Lee, Anal. Chem. 82, 9393-9400, 2010). Here we extend this capability to obtain positive and negative ion MS and MS/MS spectra in a single MS imaging experiment through polarity switching within spiral steps of each raster step. This methodology was demonstrated for the analysis of various lipid class compounds in a section of mouse brain. This allows for simultaneous imaging of compounds that are readily ionized in positive mode (e.g., phosphatidylcholines and sphingomyelins) and those that are readily ionized in negative mode (e.g., sulfatides, phosphatidylinositols and phosphatidylserines). MS/MS imaging was also performed for a few compounds in both positive and negative ion mode within the same experimental set-up. Insufficient stabilization time for the Orbitrap high voltage leads to slight deviations in observed masses, but these deviations are systematic and were easily corrected with a two-point calibration to background ions.

Indexed as

AnimalsAnionsBrain ChemistryCalibrationCationsHistocytochemistryMiceMolecular ImagingPhospholipidsSpectrometry, Mass, Electrospray IonizationSpectrometry, Mass, Matrix-Assisted Laser Desorption-IonizationAnionsCationsPhospholipids

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.