Evidence map›Paper›PMID 23580479›Full record

ArticleMagnetic resonance in medicine2014

Voltage-based device tracking in a 1.5 Tesla MRI during imaging: initial validation in swine models.

Ehud J Schmidt, Zion T H Tse, Tobias R Reichlin, Gregory F Michaud, Ronald D Watkins, Kim Butts-Pauly, Raymond Y Kwong, William Stevenson, Jeffrey Schweitzer, Israel Byrd and 1 more

Abstract readValidation Study
In one paragraph

Article in Magnetic resonance in medicine, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Interventional cardiovascular magnetic resonance: state-of-the-art.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2023
    Review
  2. Article
  3. MRI use for atrial tissue characterization in arrhythmias and for EP procedure guidance.The international journal of cardiovascular imaging · 2018
    Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Ehud J SchmidtDepartment of Radiology, Brigham and Women's Hospital, Boston, Massachusetts, USA.
Zion T H Tse
Tobias R Reichlin
Gregory F Michaud
Ronald D Watkins
Kim Butts-Pauly
Raymond Y Kwong
William Stevenson
Jeffrey Schweitzer
Israel Byrd
Charles L Dumoulin

Funding

Image Guided Therapy Center - Ultrasound-based sensor system for the monitoring of COVID-19 patientsP41EB015898 · NIBIB · BRIGHAM AND WOMEN'S HOSPITAL · PI TEMPANY, CLARE M · 2012 to 2021
$18.9M
ULTRASOUND THERAPY DELIVERY THROUGH INTACT SKULLU41RR019703 · NCRR · BRIGHAM AND WOMEN'S HOSPITAL · PI MCDANNOLD, NATHAN J. · 2005 to 2009
$17.2M
IMAGE GUIDED THERAPY CENTERP41RR019703 · NCRR · BRIGHAM AND WOMEN'S HOSPITAL · PI JOLESZ, FERENC A · 2010 to 2011
$8.6M
12-lead MRI-Compatible ECG for physiological monitoring and scanner synchronizatiR43HL110427 · NHLBI · E-TROLZ, INC · PI WARD, JAY · 2011 to 2011
$192k
Improved arrhythmia imaging with MR compatible 12-lead ECGR03EB013873 · NIBIB · BRIGHAM AND WOMEN'S HOSPITAL · PI SCHMIDT, EHUD JERUHAM · 2012 to 2013
$170k
NCRR NIH HHS P41 RR019703NCRR NIH HHS U41 RR019703NCRR NIH HHS U41-RR019703NHLBI NIH HHS HL110427-01NHLBI NIH HHS R43 HL110427NIBIB NIH HHS P41 EB015898NIBIB NIH HHS R03 EB013873NIBIB NIH HHS R03 EB013873-01A1
6 · The paper itself

Abstract

purposeVoltage-based device-tracking (VDT) systems are commonly used for tracking invasive devices in electrophysiological cardiac-arrhythmia therapy. During electrophysiological procedures, electro-anatomic mapping workstations provide guidance by integrating VDT location and intracardiac electrocardiogram information with X-ray, computerized tomography, ultrasound, and MR images. MR assists navigation, mapping, and radiofrequency ablation. Multimodality interventions require multiple patient transfers between an MRI and the X-ray/ultrasound electrophysiological suite, increasing the likelihood of patient-motion and image misregistration. An MRI-compatible VDT system may increase efficiency, as there is currently no single method to track devices both inside and outside the MRI scanner.

methodsAn MRI-compatible VDT system was constructed by modifying a commercial system. Hardware was added to reduce MRI gradient-ramp and radiofrequency unblanking pulse interference. VDT patches and cables were modified to reduce heating. Five swine cardiac VDT electro-anatomic mapping interventions were performed, navigating inside and thereafter outside the MRI.

resultsThree-catheter VDT interventions were performed at >12 frames per second both inside and outside the MRI scanner with <3 mm error. Catheters were followed on VDT- and MRI-derived maps. Simultaneous VDT and imaging was possible in repetition time >32 ms sequences with <0.5 mm errors, and <5% MRI signal-to-noise ratio (SNR) loss. At shorter repetition times, only intracardiac electrocardiogram was reliable. Radiofrequency heating was <1.5°C.

conclusionAn MRI-compatible VDT system is feasible.

Indexed as

Prostheses and ImplantsAnimalsEquipment DesignEquipment Failure AnalysisMagnetic Resonance ImagingMagneticsPilot ProjectsPlethysmography, ImpedanceSwineWireless Technology

Identifiers

PMID23580479
PMCPMC3884036

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.