Evidence map›Paper›PMID 23577067›Full record

ArticlePloS one2013

Performance of multiplex cytokine assays in serum and saliva among community-dwelling postmenopausal women.

Richard W Browne, Alpdogan Kantarci, Michael J LaMonte, Christopher A Andrews, Kathleen M Hovey, Karen L Falkner, Ali Cekici, Danielle Stephens, Robert J Genco, Frank A Scannapieco and 2 more

Abstract read
In one paragraph

Article in PloS one, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 35 papers.

0numbers the graph read from it
0cells of the map it votes in
35citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

35 citing papers in PubMed.

  1. Trial
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Association of Dental and Prosthetic Status with Oral Health-Related Quality of Life in Centenarians.International journal of environmental research and public health · 2021
    Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Richard W BrowneDepartment of Biotechnical and Clinical Laboratory Sciences, University at Buffalo, Buffalo, New York, USA. rwbrowne@buffalo.edu
Alpdogan Kantarci
Michael J LaMonte
Christopher A Andrews
Kathleen M Hovey
Karen L Falkner
Ali Cekici
Danielle Stephens
Robert J Genco
Frank A Scannapieco
Thomas E Van Dyke
Jean Wactawski-Wende

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Multiplexing arrays increase the throughput and decrease sample requirements for studies employing multiple biomarkers. The goal of this project was to examine the performance of Multiplex arrays for measuring multiple protein biomarkers in saliva and serum. Specimens from the OsteoPerio ancillary study of the Women's Health Initiative Observational Study were used. Participants required the presence of at least 6 teeth and were excluded based on active cancer and certain bone issues but were not selected on any specific condition. Quality control (QC) samples were created from pooled serum and saliva. Twenty protein markers were measured on five multiplexing array panels. Sample pretreatment conditions were optimized for each panel. Recovery, lower limit of quantification (LLOQ) and imprecision were determined for each analyte. Statistical adjustment at the plate level was used to reduce imprecision estimates and increase the number of usable observations. Sample pre-treatment improved recovery estimates for many analytes. The LLOQ for each analyte agreed with manufacturer specifications except for MMP-1 and MMP-2 which were significantly higher than reported. Following batch adjustment, 17 of 20 biomarkers in serum and 9 of 20 biomarkers in saliva demonstrated acceptable precision, defined as <20% coefficient of variation (<25% at LLOQ). The percentage of cohort samples having levels within the reportable range for each analyte varied from 10% to 100%. The ratio of levels in saliva to serum varied from 1∶100 to 28∶1. Correlations between saliva and serum were of moderate positive magnitude and significant for CRP, MMP-2, insulin, adiponectin, GM-CSF and IL-5. Multiplex arrays exhibit high levels of analytical imprecision, particularly at the batch level. Careful sample pre-treatment can enhance recovery and reduce imprecision. Following statistical adjustments to reduce batch effects, we identified biomarkers that are of acceptable quality in serum and to a lesser degree in saliva using Multiplex arrays.

Indexed as

HousingAgedAged, 80 and overBiomarkersBlood Chemical AnalysisCytokinesFemaleHumansLimit of DetectionMiddle AgedPostmenopauseSalivaBiomarkersCytokines

Identifiers

PMID23577067
PMCPMC3618114

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.