ArticleJournal of neural engineering2013
Intra-day signal instabilities affect decoding performance in an intracortical neural interface system.
Article in Journal of neural engineering, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 120 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
120 citing papers in PubMed, 247 citations in OpenAlex.
- Speech-related dorsal motor cortex activity does not interfere with iBCI cursor control.Journal of neural engineering · 2020Trial
- Volitional control of single-electrode high gamma local field potentials by people with paralysis.Journal of neurophysiology · 2019Trial
- Stable long-term BCI-enabled communication in ALS and locked-in syndrome using LFP signals.Journal of neurophysiology · 2018Trial
- Feedback control policies employed by people using intracortical brain-computer interfaces.Journal of neural engineering · 2017Trial
- Blending of brain-machine interface and vision-guided autonomous robotics improves neuroprosthetic arm performance during grasping.Journal of neuroengineering and rehabilitation · 2016Trial
- Non-causal spike filtering improves decoding of movement intention for intracortical BCIs.Journal of neuroscience methods · 2014Trial
- Human learning of noninvasive brain-computer interfaces via manifold geometry.Nature neuroscience · 2026Article
- Injectable Antifouling Adhesive Hydrogel Enables Robust Neural Interfaces for Stable ECoG Recording.Advanced healthcare materials · 2026Article
- Long-term unsupervised recalibration of cursor-based intracortical brain-computer interfaces using a hidden Markov model.Nature biomedical engineering · 2026Article
- Long-term independent use of an intracortical brain-computer interface for speech and cursor control.Nature medicine · 2026Article
- Intracortical BCI Performance is Robust to Changes in Attentional Load During Dual-Tasking.bioRxiv : the preprint server for biology · 2026Article
- Hands-free control of an assistive robotic arm for high-level paralysis.Journal of neuroengineering and rehabilitation · 2026Article
- Premotor cortex uses a compositional neural geometry to plan words.bioRxiv : the preprint server for biology · 2026Article
- Low-power differencing feature extracts spiking-band activities for high-performance intracortical brain-computer interfaces.Communications biology · 2026Article
- Closed-loop error damping in human BCI using pre-error motor cortex activity.bioRxiv : the preprint server for biology · 2026Article
- NeuroGator: A Low-Power Gating System for Asynchronous BCI Based on LFP Brain State Estimation.Brain sciences · 2026Article
- Spatial transcriptomics on an expanded dataset at the brain-electrode interface: exploration of variability and identification of novel biomarkers.Frontiers in neuroscience · 2026Article
- Long-term Intracortical Neural activity and Kinematics (LINK): An intracortical neural dataset for chronic brain-machine interfaces, neuroscience, and machine learning.Advances in neural information processing systems · 2025Article
- Decoding multi-joint hand movements from brain signals by learning a synergy-based neural manifold.Patterns (New York, N.Y.) · 2025Article
- Article
60 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 5 institutions in 1 country.
Funding
Abstract
objectiveMotor neural interface systems (NIS) aim to convert neural signals into motor prosthetic or assistive device control, allowing people with paralysis to regain movement or control over their immediate environment. Effector or prosthetic control can degrade if the relationship between recorded neural signals and intended motor behavior changes. Therefore, characterizing both biological and technological sources of signal variability is important for a reliable NIS. APPROACH: To address the frequency and causes of neural signal variability in a spike-based NIS, we analyzed within-day fluctuations in spiking activity and action potential amplitude recorded with silicon microelectrode arrays implanted in the motor cortex of three people with tetraplegia (BrainGate pilot clinical trial, IDE). MAIN
results84% of the recorded units showed a statistically significant change in apparent firing rate (3.8 ± 8.71 Hz or 49% of the mean rate) across several-minute epochs of tasks performed on a single session, and 74% of the units showed a significant change in spike amplitude (3.7 ± 6.5 µV or 5.5% of mean spike amplitude). 40% of the recording sessions showed a significant correlation in the occurrence of amplitude changes across electrodes, suggesting array micro-movement. Despite the relatively frequent amplitude changes, only 15% of the observed within-day rate changes originated from recording artifacts such as spike amplitude change or electrical noise, while 85% of the rate changes most likely emerged from physiological mechanisms. Computer simulations confirmed that systematic rate changes of individual neurons could produce a directional 'bias' in the decoded neural cursor movements. Instability in apparent neuronal spike rates indeed yielded a directional bias in 56% of all performance assessments in participant cursor control (n = 2 participants, 108 and 20 assessments over two years), resulting in suboptimal performance in these sessions. SIGNIFICANCE: We anticipate that signal acquisition and decoding methods that can adapt to the reported instabilities will further improve the performance of intracortically-based NISs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials