Evidence map›Paper›PMID 23567005›Full record

ArticleJournal of diabetes science and technology2013

A promising solution to enhance the sensocompatibility of biosensors in continuous glucose monitoring systems.

Edith E M van den Bosch, Nik H M de Bont, Jun Qiu, Onko-Jan Gelling

Open access · bronzeAbstract read
In one paragraph

Article in Journal of diabetes science and technology, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.0field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Edith E M van den BoschDSM Biomedical, Koestraat 1, 6167 RA Geleen, The Netherlands. edith.bosch-van-den@dsm.com
Nik H M de Bont
Jun Qiu
Onko-Jan Gelling
DSM (Netherlands) · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundContinuous glucose monitors (CGMs) measure glucose in real time, making it possible to improve glycemic control. A promising technique involves glucose sensors implanted in subcutaneous tissue measuring glucose concentration in interstitial fluid. A major drawback of this technique is sensor bioinstability, which can lead to unpredictable drift and reproducibility. The bioinstability is partly due to sensor design but is also affected by naturally occurring subcutaneous inflammations. Applying a nonbiofouling coating to the sensor membrane could be a means to enhancing sensocompatibility.

methodsThis study evaluates the suitability of a polyethylene-glycol-based coating on sensors in CGMs. Methods used include cross hatch, wet paper rub, paper double rub, bending, hydrophilicity, protein adsorption, bio-compatibility, hemocompatibility, and glucose/oxygen permeability testing.

resultsResults demonstrate that coating homogeneity, adhesion, integrity, and scratch resistance are good. The coating repels lysozyme and bovine serum albumin, and only a low level of fibrin and blood platelet adsorption to the coating was recorded when testing in whole human blood. Cytotoxicity, irritation, sensitization, and hemolysis were assessed, and levels suggested good biocompatibility of the coating in subcutaneous tissue. Finally, it was shown that the coating can be applied to cellulose acetate membranes of different porosity without changing their permeability for glucose and oxygen.

conclusionsThese results suggest that the mechanical properties of the coating are sufficient for the given application, that the coating is effective in preventing protein adsorption and blood clot formation on the sensor surface, and that the coating can be applied to membranes without hindering their glucose and oxygen transport.

Indexed as

Materials TestingAdsorptionBiomechanical PhenomenaBiosensing TechniquesBlood GlucoseCelluloseCoated Materials, BiocompatibleExtracellular FluidGlucoseHumansHydrophobic and Hydrophilic InteractionsMembranes, ArtificialMonitoring, PhysiologicOxygenPolyethylene GlycolsSensitivity and SpecificityacetylcelluloseBlood GlucoseCelluloseCoated Materials, BiocompatibleGlucoseMembranes, ArtificialOxygenPolyethylene GlycolsSerum Albumin, Bovine

Identifiers

PMID23567005
PMCPMC3737648
OpenAlexW1991807693

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked