ArticleNeuroImage2013
Whole-head rapid fMRI acquisition using echo-shifted magnetic resonance inverse imaging.
Article in NeuroImage, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Steady-state free precession for TMagnetic resonance in medicine · 2025Article
- Statistical power or more precise insights into neuro-temporal dynamics? Assessing the benefits of rapid temporal sampling in fMRI.Progress in neurobiology · 2021Review
- 15 Years MR-encephalography.Magma (New York, N.Y.) · 2021Review
- Sampling Rate Effects on Resting State fMRI Metrics.Frontiers in neuroscience · 2019Article
- Evaluation of SLIce Dithered Enhanced Resolution Simultaneous MultiSlice (SLIDER-SMS) for human fMRI.NeuroImage · 2018Article
- Simultaneous multi-slice inverse imaging of the human brain.Scientific reports · 2017Article
- Focused Ultrasound Help Realize High Spatiotemporal Brain Imaging?-A Concept on Acousto-Electrophysiological Neuroimaging.IEEE transactions on bio-medical engineering · 2016Article
- Increased fMRI Sensitivity at Equal Data Burden Using Averaged Shifted Echo Acquisition.Frontiers in neuroscience · 2016Article
- Electrocorticography Reveals Enhanced Visual Cortex Responses to Visual Speech.Cerebral cortex (New York, N.Y. : 1991) · 2015Article
- Improving the spatial resolution of magnetic resonance inverse imaging via the blipped-CAIPI acquisition scheme.NeuroImage · 2014Article
- Using precise word timing information improves decoding accuracy in a multiband-accelerated multimodal reading experiment.Cognitive neuropsychologyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
The acquisition time of BOLD contrast functional MRI (fMRI) data with whole-brain coverage typically requires a sampling rate of one volume in 1-3s. Although the volumetric sampling time of a few seconds is adequate for measuring the sluggish hemodynamic response (HDR) to neuronal activation, faster sampling of fMRI might allow for monitoring of rapid physiological fluctuations and detection of subtle neuronal activation timing information embedded in BOLD signals. Previous studies utilizing a highly accelerated volumetric MR inverse imaging (InI) technique have provided a sampling rate of one volume per 100 ms with 5mm spatial resolution. Here, we propose a novel modification of this technique, the echo-shifted InI, which allows TE to be longer than TR, to measure BOLD fMRI at an even faster sampling rate of one volume per 25 ms with whole-brain coverage. Compared with conventional EPI, echo-shifted InI provided an 80-fold speedup with similar spatial resolution and less than 2-fold temporal SNR loss. The capability of echo-shifted InI to detect HDR timing differences was tested empirically. At the group level (n=6), echo-spaced InI was able to detect statistically significant HDR timing differences of as low as 50 ms in visual stimulus presentation. At the level of individual subjects, significant differences in HDR timing were detected for 400 ms stimulus-onset differences. Our results also show that the temporal resolution of 25 ms is necessary for maintaining the temporal detecting capability at this level. With the capabilities of being able to distinguish the timing differences in the millisecond scale, echo-shifted InI could be a useful fMRI tool for obtaining temporal information at a time scale closer to that of neuronal dynamics.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.