Evidence map›Paper›PMID 23563054›Full record

ArticleInteractive cardiovascular and thoracic surgery2013

Haemodynamic comparison of a novel flow-divider Optiflo geometry and a traditional total cavopulmonary connection.

Kalpi Desai, Christopher M Haggerty, Kirk R Kanter, Jarek Rossignac, Thomas L Spray, Mark A Fogel, Ajit P Yoganathan

Open access · bronzeAbstract readComparative Study
In one paragraph

Article in Interactive cardiovascular and thoracic surgery, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.6field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Kalpi DesaiWallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology & Emory University, Atlanta, GA 30332, USA.
Christopher M Haggerty
Kirk R Kanter
Jarek Rossignac
Thomas L Spray
Mark A Fogel
Ajit P Yoganathan
Georgia Institute of Technology · USChildren's Hospital of Philadelphia · USEmory University · USThe Wallace H. Coulter Department of Biomedical Engineering · US

Funding

Improving Flow Dynamics in Fontan SurgeriesR01HL067622 · NHLBI · GEORGIA INSTITUTE OF TECHNOLOGY · PI YOGANATHAN, AJIT P · 2002 to 2006
$5.2M
Understanding mechanisms of Fontan failure and key predictors for patient outcomeR01HL098252 · NHLBI · GEORGIA INSTITUTE OF TECHNOLOGY · PI YOGANATHAN, AJIT P · 2010 to 2013
$3.0M
NHLBI NIH HHS HL098252NHLBI NIH HHS HL67622
6 · The paper itself

Abstract

objectivesThe total cavopulmonary connection (TCPC), the current palliation of choice for single-ventricle heart defects, is typically created with a single cylindrical tunnel or conduit routing inferior vena caval (IVC) flow to the pulmonary arteries. Previous studies have shown the haemodynamic efficiency of the TCPC to be sub-optimal due to the collision of vena caval flow, thus placing an extra energy burden on the single ventricle. The use of a bifurcated graft as the Fontan baffle (i.e. the 'Optiflo') has previously been proposed on the basis of theoretically improved flow efficiency; however, anatomical constraints may limit its effectiveness in some patients.

methodsIn this study, an alternative approach to flow bifurcation is proposed, where a triangular insert is placed at the distal end of the IVC graft. The proof of concept for this design is demonstrated in two steps: first, determining the optimal insert size at a fixed Fontan graft size through a parametric study; then, characterizing the efficiency as a function of graft size when compared with a TCPC control. TCPC power loss and IVC flow distribution were the primary metrics of interest and were evaluated under both resting and simulated exercise conditions using an in-house computational fluid dynamics solver.

resultsResults demonstrated that there was an optimal insert size that improved efficiency compared with the TCPC. For an 18-mm Fontan baffle, TCPC power loss was 4.1 vs 3.7 mW with the optimal flow-divider. The optimal insert was then scaled up for a 20-mm graft, with a similar reduction in power loss observed. Flow distribution results were inconsistent, based on sensitivity to the placement of the insert within the baffle.

conclusionThis study demonstrated proof of concept that the flow-divider has the potential to reduce power loss and streamline IVC flow through the TCPC. An appropriate size for the insert in proportion to the Fontan baffle size was identified that reduced losses compared with a TCPC control under both resting and simulated exercise flow conditions.

Indexed as

Blood Vessel ProsthesisHemodynamicsBlood Vessel Prosthesis ImplantationComputer SimulationExerciseFontan ProcedureHeart Defects, CongenitalHumansMaterials TestingModels, CardiovascularProsthesis DesignPulmonary ArteryVena Cava, InferiorCongenital heartFontanHaemodynamicsSingle ventricle

Identifiers

PMID23563054
PMCPMC3686377
OpenAlexW2171608357

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.