Evidence map›Paper›PMID 23559698›Full record

ArticleIndian journal of community medicine : official publication of Indian Association of Preventive & Social Medicine2013

Equipment errors: a prevalent cause for fallacy in blood pressure recording - a point prevalence estimate from an Indian health university.

Badrinarayan Mishra, Nidhi Dinesh Sinha, Hitesh Gidwani, Sushil Kumar Shukla, Abhishek Kawatra, Sc Mehta

Open access · goldAbstract read
In one paragraph

Article in Indian journal of community medicine : official publication of Indian Association of Preventive & Social Medicine, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.4field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Overview of blood pressure measurement by Brazilian health professionals.Journal of clinical hypertension (Greenwich, Conn.) · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Badrinarayan MishraDepartment of Community Medicine, R. D. Gardi Medical College, Surasa, Ujjain, MP, India.
Nidhi Dinesh Sinha
Hitesh Gidwani
Sushil Kumar Shukla
Abhishek Kawatra
Sc Mehta
Pravara Institute of Medical Sciences · INRuxmaniben Deepchand Gardi Medical College · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundBlood pressure (BP) recording is the most commonly measured clinical parameter. Standing mercury sphygmomanometer is the most widely used equipment to record this. However, recording by sphygmomanometer is subject to observer and instrumental error. The different sources of equipment error are faulty manometer tube calibration, baseline deviations and improper arm bladder cuff dimensions. This is further compounded by a high prevalence of arm bladder miss-cuffing in the target population.

objectivesThe study was designed to assess the presence of equipment malcalibrations, cuff miss-matching and their effect on BP recording. MATERIALS AND

methodsA cross-sectional check of all operational sphygmomanometers in a health university was carried out for the length of the manometer tube, deviation of resting mercury column from "0" level, the width and length of arm bladder cuff and extent of bladder cuff-mismatch with respect to outpatient attending population.

resultsFrom the total of 50 apparatus selected, 39 (78%) were from hospital setups and 11 (22%) from pre-clinical departments. A manometer height deficit of 13 mm was recorded in 36 (92.23%) of the equipment in hospital and 11 (100%) from pre-clinical departments. Instruments from both settings showed significant deviation from recommended dimensions in cuff bladder length, width and length to width ratio (P < 0.001). Significant number of apparatus from hospital setups showed presence of mercury manometer baseline deviation either below or above 0 mmHg at the resting state (χ(2) = 5.61, D. F. = 1, P = 0.02). Positive corelationship was observed between manometer height deficit, baseline deviation and width of arm cuff bladder (Pearson correlation, P < 0.05). Bladder cuff mismatching in response to the target population was found at 48.52% for males and 36.76% for females. The cumulative effect of these factors can lead to an error in the range of 10-12 mmHg.

conclusionFaulty equipments and prevalent arm bladder cuff-mismatching can be important barriers to accurate BP measurement.

Indexed as

Blood pressureinstrument errormiss-cuffing

Identifiers

PMID23559698
PMCPMC3612291
OpenAlexW2074190758

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked