Evidence map›Paper›PMID 23549923›Full record

ArticleMedical & biological engineering & computing2013

Monitoring intracellular, interstitial, and intravascular volume changes during fluid management procedures.

Leslie D Montgomery, Wayne A Gerth, Richard W Montgomery, Susie Q Lew, Michael M Klein, Julian M Stewart, Marvin S Medow, Manuel T Velasquez

Erratum issuedAbstract read
In one paragraph

Article in Medical & biological engineering & computing, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
0.6field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 24 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Bioimpedance monitoring of cellular hydration during hemodialysis therapy.Hemodialysis international. International Symposium on Home Hemodialysis · 2017
    Article
  8. Article
4 · The record

Corrections and comments

  • Erratum issued
    Medow, Marvin S [added]
5 · Who and what money

Authors and funding

8 authors at 4 institutions in 1 country.

Leslie D MontgomeryLDM Associates, 1764 Emory Street, San Jose, CA 95126, USA. pmontgomery@telis.org
Wayne A Gerth
Richard W Montgomery
Susie Q Lew
Michael M Klein
Julian M Stewart
Marvin S Medow
Manuel T Velasquez
Emory and Henry College · USGeorge Washington University · USNew York Medical College · USEMT Associates (United States) · US

Funding

Measuring Intra/Extracellular Volume and HemodynamicsR44HL074524 · NHLBI · LDM ASSOCIATES · PI MONTGOMERY, LESLIE DAVID · 2006 to 2007
$1.2M
Measuring Intra/Extracellular Volume and HemodynamicsR43HL074524 · NHLBI · LDM ASSOCIATES · PI MONTGOMERY, LESLIE DAVID · 2003 to 2003
$100k
NHLBI NIH HHS 1 R43 HL074524-01NHLBI NIH HHS 2 R44 HL074524-02A2NHLBI NIH HHS R43 HL074524NHLBI NIH HHS R44 HL074524
6 · The paper itself

Abstract

The bioimpedance spectroscopic (BIS) analytical algorithm described in this report allows for the non-invasive measurement of intravascular, interstitial, and intracellular volume changes during various fluid management procedures. The purpose of this study was to test clinical use feasibility and to demonstrate the validity of the BIS algorithm in computing compartmental volume shifts in human subjects undergoing fluid management treatment. Validation was performed using volume changes recorded from 20 end stage renal disease patients. The validation procedure involved mathematically deriving post hoc hematocrit profiles from the BIS data-generated fluid redistribution time profiles. These derived hematocrit profiles were then compared to serial hematocrit values measured simultaneously by a CritLine(®) monitor during 60 routine hemodialysis sessions. Regression and Bland-Altman analyses confirm that the BIS algorithm can be used to reliably derive the continuous and real-time rates of change of the compartmental fluid volumes. Regression results yielded a R (2) > 0.99 between the two measures of hematocrit at different times during dialysis. The slopes of the regression equations at the different times were nearly identical, demonstrating an almost one-to-one correspondence between the BIS and CritLine(®) hematocrits. Bland-Altman analysis show that the BIS algorithm can be used interchangeably with the CritLine(®) monitor for the measurement of hematocrit. The present study demonstrates for the first time that BIS can provide real-time continuous measurements of compartmental intravascular, interstitial and intracellular fluid volume changes during fluid management procedures when used in conjunction with this new algorithm.

Indexed as

AgedBody FluidsDielectric SpectroscopyElectric ImpedanceFemaleHematocritHumansIntracellular SpaceKidney Failure, ChronicLeast-Squares AnalysisLegMaleMiddle AgedModels, BiologicalMonitoring, PhysiologicRenal Dialysis

Identifiers

PMID23549923
PMCPMC3757131
OpenAlexW2109955637

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.