Evidence map›Paper›PMID 23532488›Full record

ArticleIndian journal of orthopaedics2013

Factors affecting range of motion in total knee arthroplasty using high flexion prosthesis: A prospective study.

Kantilal H Sancheti, Parag K Sancheti, Ashok K Shyam, Rajeev Joshi, Kailash Patil, Anubhav Jain

Abstract read
In one paragraph

Article in Indian journal of orthopaedics, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 1 pooled it
3.8field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 1 synthesis or guideline pooled it, 31 citations in OpenAlex.

  1. Posterior-stabilized versus cruciate-retained implants for total knee arthroplasty: a meta-analysis of clinical trials.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2019
    Pooled it
  2. Effect of surgical closing in total knee arthroplasty at flexion or extension: a prospective, randomized study.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2014
    Trial
  3. Joint-specific measures improve risk adjustment in total knee arthroplasty: A machine learning approach.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2026
    Article
  4. Article
  5. Article
  6. Article
  7. Observational
  8. Article
  9. Article
  10. Article
  11. Article
  12. Indian Journal of Orthopaedics: Journey continues.Indian journal of orthopaedics · 2013
    Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Kantilal H SanchetiDepartment of Arthroplasty, Sancheti Institute of Orthopaedics and Rehabilitation, 16 Shivaji Nagar, Pune, Maharashtra, India.
Parag K Sancheti
Ashok K Shyam
Rajeev Joshi
Kailash Patil
Anubhav Jain
Sancheti Institute For Orthopaedics & Rehabilitation · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundHigh flexion implants have been reported to provide better range of motion (ROM). The few studies analyzing the factors affecting the ROM are scarce. This study aims to find the factors that affect ROM when using a high flex knee design (INDUS knee). MATERIALS AND

methodsTwo hundred and fifty three consecutive patients of total knee arthroplasty (TKA) done by using INDUS knee prosthesis between Sept 2008 and Sept 2009 were included in the study. The cases with osteoarthritis (OA) and Rheumatoid arthritis (RA) were included in study. 5 patients were lost to followup and 248 patients (267 knees, 19 bilateral, 221 OA, and 46 RA) were analyzed for the following factors - sex, age, body mass index (BMI), preoperative ROM, flexion deformity, preoperative total knee score and functional score, time of tourniquet release and patella resurfacing. Subgroup classification using above factors was performed and statistical analysis of effect of all the above factors on final knee ROM was done. Assessment was done preoperatively and at 3 months, 6 months and 1 year postoperatively. The final outcome evaluation was done at one year followup.

resultsThe mean age was 68.2 years (range 40-89 years) with 79 males and 189 females. The mean knee range improved from 97.62 ± 11° to 132 ± 8°. Factors that positively affect ROM of INDUS knee prosthesis at the end of 1 year were preoperative ROM, total knee score and functional score, and diagnosis of osteoarthritis, whereas BMI, preoperative flexion deformity has a negative influence on final flexion at the end of 1 year. Age and gender of the patients, patella resurfacing, and use of two different tourniquet protocols did not affect the final outcome.

conclusionPreoperative ROM and preoperative functional status are the most important factors affecting final range. Patients should be counseled accordingly and made to understand these factors.

Indexed as

High flex knee prosthesisrange of motiontotal knee arthroplasty

Identifiers

PMID23532488
PMCPMC3601234
OpenAlexW1990820668

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.