Evidence map›Paper›PMID 23496994›Full record

ArticleBMC health services research2013

Assessing the outcomes of implantable cardioverter defibrillator treatment in a real world setting: results from hospital record data.

Simone Ghislandi, Aleksandra Torbica, Giuseppe Boriani

Open access · goldAbstract readComparative Study
In one paragraph

Article in BMC health services research, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.0field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 3 institutions in 2 countries.

Simone GhislandiDepartment for Policy Analysis and Public Management, Università Commerciale Luigi Bocconi, Milan, Italy. aleksandra.torbica@unibocconi.it.
Aleksandra Torbica
Giuseppe Boriani
Association of European Renewable Energy Research Centres · BEBocconi University · ITUniversity of Bologna · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundA plethora of clinical studies have assessed the benefits of implantable cardioverter defibrillators (ICDs) and supported their use in clinical practice. However, evidence on the safety and efficacy of ICDs appears insufficient to support expansion of their use in clinical practice, and more information on their impact in real life settings is warranted. This paper aims to investigate the impact of ICDs using a large administrative dataset reflecting actual clinical practice.

methodsData were obtained from the hospital discharge database of the Friuli Venezia Giulia region in Italy containing patient-level information on 169,488 cases. Data on mortality outside hospital were obtained from regional sources. Exact matching method was used to estimate the outcomes associated with ICDs: mortality, length of stay, re-hospitalization and regional expenditure. The method was applied in two steps. First, patients with ICDs were matched with those without using the following: age class (by 5 years), gender, year of admission, type of admission (day hospital vs. ordinary) and primary diagnosis. In the second step, matching included also Charlson Comorbidities Index. Exact matching average treatment effect on the treated (ATT) was used as a main measure of impact.

resultsCompared with matched controls, treatment with ICDs was associated with lower mortality (absolute risk reduction 10.6% at 1 year and 8.3% at 2 and 8.4% at 3 years, p < 0.001 and hazard ratio 0.80, p < 0.001), greater regional expenditure at index hospitalization (ATT: €9459.64, p < 0.001) and during follow up (ATT: €1707.29, p < 0.001) and higher re-hospitalization rate (ATT: 0.53, p < 0.001). No significant difference was found for length of stay (9.07 vs. 8.86 days). The results were maintained after more restrictive matching was applied.

conclusionsAssessing the impact of innovative, expensive medical technologies on the basis of real world data is warranted, especially when there are barriers to implementation. Hospital administrative datasets can be of great value when a technology such as the ICD is implemented in a relatively small sample of patients, to allow use of exact matching techniques.

Indexed as

Defibrillators, ImplantableHospital RecordsAgedConfidence IntervalsDatabases, FactualFemaleHumansItalyLength of StayMaleMatched-Pair AnalysisMiddle AgedOutcome Assessment, Health CarePatient ReadmissionSurvival Rate