Evidence map›Paper›PMID 23479498›Full record

ArticleApplied physics letters2013

Breaking the acoustic diffraction limit via nonlinear effect and thermal confinement for potential deep-tissue high-resolution imaging.

Baohong Yuan, Yanbo Pei, Jayanth Kandukuri

Abstract read
In one paragraph

Article in Applied physics letters, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Thermo- and pH-sensitive nanoparticles of poly (Experimental biology and medicine (Maywood, N.J.) · 2022
    Article
  3. Biomedical optics express · 2020
    Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Development of Ultrasound-switchable Fluorescence Imaging Contrast Agents based on Thermosensitive Polymers and Nanoparticles.IEEE journal of selected topics in quantum electronics : a publication of the IEEE Lasers and Electro-optics Society
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Baohong YuanUltrasound and Optical Imaging Laboratory, Department of Bioengineering, The University of Texas at Arlington, Arlington, Texas 76019, USA and Joint Biomedical Engineering Program, The University of Texas at Arlington and The University of Texas Southwestern Medical Center at Dallas, Dallas, Texas 75390, USA.
Yanbo Pei
Jayanth Kandukuri

Funding

FRET-based Ultrasound-Switchable Fluorescence ImagingR15EB012312 · NIBIB · UNIVERSITY OF TEXAS ARLINGTON · PI YUAN, BAOHONG · 2010 to 2010
$397k
NIBIB NIH HHS R15 EB012312
6 · The paper itself

Abstract

Our recently developed ultrasound-switchable fluorescence (USF) imaging technique showed that it was feasible to conduct high-resolution fluorescence imaging in a centimeter-deep turbid medium. Because the spatial resolution of this technique highly depends on the ultrasound-induced temperature focal size (UTFS), minimization of UTFS becomes important for further improving the spatial resolution USF technique. In this study, we found that UTFS can be significantly reduced below the diffraction-limited acoustic intensity focal size via nonlinear acoustic effects and thermal confinement by appropriately controlling ultrasound power and exposure time, which can be potentially used for deep-tissue high-resolution imaging.

Identifiers

PMID23479498
PMCPMC3585748

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.