ArticleMolecular & cellular proteomics : MCP2013
Defining, comparing, and improving iTRAQ quantification in mass spectrometry proteomics data.
Article in Molecular & cellular proteomics : MCP, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 27 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
27 citing papers in PubMed.
- Differential protein expression analysis of quantitative mass spectrometry data using DEqMS.Nature protocols · 2026Review
- IQUP identifies quantitatively unreliable spectra with machine learning for isobaric labeling-based proteomics.Scientific reports · 2025Article
- Quantitative proteomic profiling reveals sexual dimorphism in the retina and RPE of C57BL6 mice.Biology of sex differences · 2024Article
- A Causal Model of Ion Interference Enables Assessment and Correction of Ratio Compression in Multiplex Proteomics.Molecular & cellular proteomics : MCP · 2024Article
- Advances in neuroproteomics for neurotrauma: unraveling insights for personalized medicine and future prospects.Frontiers in neurology · 2023Review
- The Two Weapons against Bacterial Biofilms: Detection and Treatment.Antibiotics (Basel, Switzerland) · 2021Review
- Impact of whole-body versus nose-only inhalation exposure systems on systemic, respiratory, and cardiovascular endpoints in a 2-month cigarette smoke exposure study in the ApoEJournal of applied toxicology : JAT · 2021Article
- Quantitative Proteomics Using Isobaric Labeling: A Practical Guide.Genomics, proteomics & bioinformatics · 2021Review
- Enhanced Biosynthesis of Fatty Acids Is Associated with the Acquisition of Ciprofloxacin Resistance in Edwardsiella tarda.mSystems · 2021Article
- Proteomics of Primary Uveal Melanoma: Insights into Metastasis and Protein Biomarkers.Cancers · 2021Article
- Disease-specific platelet signaling defects in idiopathic pulmonary arterial hypertension.American journal of physiology. Lung cellular and molecular physiology · 2021Article
- Multi-Q 2 software facilitates isobaric labeling quantitation analysis with improved accuracy and coverage.Scientific reports · 2021Article
- Quantitative proteomic comparison of myofibroblasts derived from bone marrow and cornea.Scientific reports · 2020Article
- DEqMS: A Method for Accurate Variance Estimation in Differential Protein Expression Analysis.Molecular & cellular proteomics : MCP · 2020Article
- HyperQuant-A Computational Pipeline for Higher Order Multiplexed Quantitative Proteomics.ACS omega · 2020Article
- mRNA display with library of even-distribution reveals cellular interactors of influenza virus NS1.Nature communications · 2020Article
- Multi-omics systems toxicology study of mouse lung assessing the effects of aerosols from two heat-not-burn tobacco products and cigarette smoke.Computational and structural biotechnology journal · 2020Article
- Sum of peak intensities outperforms peak area integration in iTRAQ protein expression measurement by LC-MS/MS using a TripleTOF 5600+ platform.Bioscience reports · 2019Article
- Quantitative Early Auxin Root Proteomics Identifies GAUT10, a Galacturonosyltransferase, as a Novel Regulator of Root Meristem Maintenance.Molecular & cellular proteomics : MCP · 2019Article
- A Review on Quantitative Multiplexed Proteomics.Chembiochem : a European journal of chemical biology · 2019Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The purpose of this study was to generate a basis for the decision of what protein quantities are reliable and find a way for accurate and precise protein quantification. To investigate this we have used thousands of peptide measurements to estimate variance and bias for quantification by iTRAQ (isobaric tags for relative and absolute quantification) mass spectrometry in complex human samples. A549 cell lysate was mixed in the proportions 2:2:1:1:2:2:1:1, fractionated by high resolution isoelectric focusing and liquid chromatography and analyzed by three mass spectrometry platforms; LTQ Orbitrap Velos, 4800 MALDI-TOF/TOF and 6530 Q-TOF. We have investigated how variance and bias in the iTRAQ reporter ions data are affected by common experimental variables such as sample amount, sample fractionation, fragmentation energy, and instrument platform. Based on this, we have suggested a concept for experimental design and a methodology for protein quantification. By using duplicate samples in each run, each experiment is validated based on its internal experimental variation. The duplicates are used for calculating peptide weights, unique to the experiment, which is used in the protein quantification. By weighting the peptides depending on reporter ion intensity, we can decrease the relative error in quantification at the protein level and assign a total weight to each protein that reflects the protein quantitation confidence. We also demonstrate the usability of this methodology in a cancer cell line experiment as well as in a clinical data set of lung cancer tissue samples. In conclusion, we have in this study developed a methodology for improved protein quantification in shotgun proteomics and introduced a way to assess quantification for proteins with few peptides. The experimental design and developed algorithms decreased the relative protein quantification error in the analysis of complex biological samples.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.