ArticleMedical physics2013
Integration of cardiac and respiratory motion into MRI roadmaps fused with x-ray.
Article in Medical physics, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02737579 (XFM), which is not on this map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
XFM: (X-ray Fused With MRI) Guided Cardiac Catheterization
Who cites it
12 citing papers in PubMed.
- Real-time respiratory motion compensated roadmaps for hepatic arterial interventions.Medical physics · 2021Article
- Fusion imaging for transcatheter mitral and tricuspid interventions.Annals of translational medicine · 2020Review
- X-ray fused with MRI guidance of pre-selected transcatheter congenital heart disease interventions.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2019Article
- An MR-Based Model for Cardio-Respiratory Motion Compensation of Overlays in X-Ray Fluoroscopy.IEEE transactions on medical imaging · 2018Article
- Improving the cardiac cath-lab interventional imaging eco-system.Translational pediatrics · 2018Article
- Novel Three-Dimensional Image Fusion Software to Facilitate Guidance of Complex Cardiac Catheterization : 3D image fusion for interventions in CHD.Pediatric cardiology · 2017Article
- Unsupervised Learning for Robust Respiratory Signal Estimation From X-Ray Fluoroscopy.IEEE transactions on medical imaging · 2017Article
- X-ray Fused With Magnetic Resonance Imaging to Guide Endomyocardial Biopsy of a Right Ventricular Mass.Radiologic technology · 2016Article
- Interventional CMR: Clinical applications and future directions.Current cardiology reports · 2015Review
- Roadmaps show the way: coregistration to enhance structural heart interventions.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2013Article
- Article
- Multimodality 3-dimensional image integration for congenital cardiac catheterization.Methodist DeBakey cardiovascular journalReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
purposeVolumetric roadmaps overlaid on live x-ray fluoroscopy may be used to enhance image guidance during interventional procedures. These roadmaps are often static and do not reflect cardiac or respiratory motion. In this work, the authors present a method for integrating cardiac and respiratory motion into magnetic resonance imaging (MRI)-derived roadmaps to fuse with live x-ray fluoroscopy images, and this method was tested in large animals.
methodsReal-time MR images were used to capture cardiac and respiratory motion. Nonrigid registration was used to calculate motion fields to deform a reference end-expiration, end-diastolic image to different cardiac and respiratory phases. These motion fields were fit to separate affine motion models for the aorta and proximal right coronary artery. Under x-ray fluoroscopy, an image-based navigator and ECG signal were used as inputs to deform the roadmap for live overlay. The in vivo accuracy of motion correction was measured in four swine as the ventilator tidal volume was varied.
resultsMotion correction reduced the root-mean-square error between the roadmaps and manually drawn centerlines, even under high tidal volume conditions. For the aorta, the error was reduced from 2.4 ± 1.5 mm to 2.2 ± 1.5 mm (p < 0.05). For the proximal right coronary artery, the error was reduced from 8.8 ± 16.2 mm to 4.3 ± 5.2 mm (p < 0.001). Using real-time MRI and an affine motion model it is feasible to incorporate physiological cardiac and respiratory motion into MRI-derived roadmaps to provide enhanced image guidance for interventional procedures.
conclusionsA method has been presented for creating dynamic 3D roadmaps that incorporate cardiac and respiratory motion. These roadmaps can be overlaid on live X-ray fluoroscopy to enhance image guidance for cardiac interventions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.