ReviewJournal of magnetic resonance (San Diego, Calif. : 1997)2013
Massively parallel MRI detector arrays.
Review in Journal of magnetic resonance (San Diego, Calif. : 1997), 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 77 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
77 citing papers in PubMed.
- A Hybrid RF Coil for Whole-Brain Imaging in Non-Human Primates at 7 T.Magnetic resonance in medicine · 2026Article
- Improved dynamic MRI of the wrist and heart at 0.55 T enabled by rapid 3D printed flexible coils.Nature communications · 2026Article
- Article
- Insights into Accelerated MRI Protocols for Pediatric Brain Assessment in Emergency Cases.Diagnostics (Basel, Switzerland) · 2026Article
- Ultra-high gradient connectomics and microstructure MRI scanner for imaging of human brain circuits across scales.Nature biomedical engineering · 2026Article
- A unipolar head gradient for high-field MRI without encoding ambiguity.Magnetic resonance in medicine · 2026Article
- High-density MRI coil arrays with integrated field monitoring systems for human connectome mapping.Magnetic resonance in medicine · 2025Article
- A 128-channel receive array with enhanced signal-to-noise ratio performance for 10.5T brain imaging.Magnetic resonance in medicine · 2025Article
- A 60-channel high-density flexible receive array for pediatric abdominal MRI.Magnetic resonance in medicine · 2025Article
- Printed, dual-loop magnetic field sniffer probe for bench measurements on radio frequency MRI coils.HardwareX · 2025Article
- Adaptable, wearable, and stretchable coils: A review.Magnetic resonance in medicine · 2025Review
- A deep brain stimulation-conditioned RF coil for 3T MRI.Magnetic resonance in medicine · 2025Article
- Nonlinear metamaterials enhanced surface coil array for parallel magnetic resonance imaging.Nature communications · 2024Article
- Mouse Cardiovascular Imaging.Current protocols · 2024Review
- Performance of receive head arrays versus ultimate intrinsic SNR at 7 T and 10.5 T.Magnetic resonance in medicine · 2024Article
- Subwavelength dielectric waveguide for efficient travelling-wave magnetic resonance imaging.Nature communications · 2024Article
- A 128-channel receive array for cortical brain imaging at 7 T.Magnetic resonance in medicine · 2023Article
- Technical Advancements in Abdominal Diffusion-weighted Imaging.Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2023Review
- A cryogenic 14-channelMagnetic resonance in medicine · 2023Article
- Trade-off between preamplifier noise figure and decoupling in MRI detectors.Magnetic resonance in medicine · 2023Article
17 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
Abstract
Originally proposed as a method to increase sensitivity by extending the locally high-sensitivity of small surface coil elements to larger areas via reception, the term parallel imaging now includes the use of array coils to perform image encoding. This methodology has impacted clinical imaging to the point where many examinations are performed with an array comprising multiple smaller surface coil elements as the detector of the MR signal. This article reviews the theoretical and experimental basis for the trend towards higher channel counts relying on insights gained from modeling and experimental studies as well as the theoretical analysis of the so-called "ultimate" SNR and g-factor. We also review the methods for optimally combining array data and changes in RF methodology needed to construct massively parallel MRI detector arrays and show some examples of state-of-the-art for highly accelerated imaging with the resulting highly parallel arrays.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.