SynthesisThe Cochrane database of systematic reviews2013
Extramedullary fixation implants and external fixators for extracapsular hip fractures in adults.
Synthesis in The Cochrane database of systematic reviews, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 1 synthesis or guideline pooled it, 62 citations in OpenAlex.
- Surgical interventions for treating extracapsular hip fractures in older adults: a network meta-analysis.The Cochrane database of systematic reviews · 2022Pooled it
- No effect of hydroxyapatite-coated sliding hip screw threads on screw migration in the femoral head/neck of pertrochanteric fractures: a randomized controlled trial using radiostereometric analysis.Journal of orthopaedic surgery and research · 2023Trial
- Trial
- Advances in internal fixation methods for intertrochanteric femoral fractures: A narrative review.Pakistan journal of medical sciences · 2026Review
- Identifying High-Risk Patients for Postoperative Renal Complications Following Femoral Intramedullary Fixation: A NSQIP Study.Orthopedic reviews · 2025Article
- Trans-Table Intraoperative Fluoroscopic Technique for Obtaining a True Lateral View of the Proximal Femur in the Lateral Decubitus Position.The archives of bone and joint surgery · 2023Article
- Outcome of unstable pertrochanteric fractures in high-risk geriatric treated with external fixators.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2022Article
- Article
- Fixation of intertrochanteric femur fractures using the SIGN intramedullary nail augmented by a lateral plate in a resource-limited setting without intraoperative fluoroscopy: assessment of functional outcomes at one-year follow-up at Juba Teaching Hospital.OTA international : the open access journal of orthopaedic trauma · 2021Article
- Article
- Functional and Radiological Outcome of Unstable Intertrochanteric Fracture Post Dynamic Hip Screw Fixation.Cureus · 2019Article
- A Survey of Current Practices and Preferences for Internal Fixation of Trochanteric Fractures of the Femur in Brazil.Cureus · 2018Article
- The tip-apex distance in the X-Bolt dynamic plating system.Bone & joint research · 2017Article
- A case report of Progressive subluxation leading to an anterior dislocation of the hip following sliding hip screw fixation for pertrochanteric Extracapsular 4 part fracture neck of femur.Clinical case reports · 2015Article
- Extramedullary fixation of trochanteric hip fracture.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2014Article
- Outcomes after trifocal femoral fractures.Case reports in surgery · 2014Article
Corrections and comments
- Update of
Authors and funding
2 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundExtramedullary fixation of hip fractures involves the application of a plate and screws to the lateral side of the proximal femur. In external fixators, the stabilising component is held outside the thigh by pins or screws driven into the bone. This is an update of a Cochrane review first published in 1998, and last updated in 2005.
objectivesTo assess the relative effects of different types of extramedullary fixation implant, as well as external fixators, for treating extracapsular proximal femoral (hip) fractures in adults. SEARCH
methodsWe searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register (July 2011), the Cochrane Central Register of Controlled Trials (The Cochrane Library 2011, Issue 2), MEDLINE (1966 to June Week 4 2011), EMBASE (1988 to 2011 Week 25), various other databases, conference proceedings and reference lists. SELECTION CRITERIA: Randomised or quasi-randomised controlled trials comparing extramedullary implants or external fixators for fixing extracapsular hip fracture in adults were included. DATA COLLECTION AND ANALYSIS: Two review authors independently selected trials, assessed risk of bias and extracted data. Data were pooled where appropriate. MAIN
resultsThe 18 included trials tested seven comparisons in a total of 2615 mainly female and older participants with a total of 2619 fractures. All trials had methodological flaws that may affect the validity of their results.Three trials of 355 participants comparing a fixed nail plate (Jewett or McLaughlin) with the sliding hip screw (SHS) found an increased risk of fixation failure for fixed nail plates.The two trials of 433 participants comparing the Resistance Augmented Bateaux (RAB) plate with the SHS had contrasting results, notably in terms of operative complications, fixation failure and anatomical restoration.One trial of 100 participants comparing the Pugh nail and the SHS found no significant difference between implants.Three trials of 458 participants compared the Medoff plate with the SHS. There was a trend to higher blood losses and longer operation times for the Medoff plate along with a trend to a lower risk of fixation failure with the Medoff plate for unstable trochanteric fractures.Two trials of 676 participants compared the Medoff plate with three different screw-plate systems. There were no statistically significant differences in outcome for trochanteric fractures. For subtrochanteric fractures, there was a lower fixation failure rate for the Medoff plate but no evidence for differences in longer-term outcomes.Four trials of 396 participants comparing the Gotfried percutaneous compression plate (PCCP) with a SHS found a trend to lower blood loss and transfusion requirements for the PCCP but no other confirmed differences in outcomes between implants. Three of the trials reported intra-operative problems with the PCCP, some of which precluded its use.Three trials of 200 participants comparing external fixation with a SHS found less operative trauma for the external fixation. Final outcome appeared similar. AUTHORS'
conclusionsThe markedly increased fixation failure rate of fixed nail plates compared with the SHS is a major consideration and thus the SHS appears preferable.There was insufficient evidence from other comparisons of extramedullary implants or on the use of external fixators to draw definite conclusions.