Evidence map›Paper›PMID 23450528›Full record

SynthesisThe Cochrane database of systematic reviews2013

Extramedullary fixation implants and external fixators for extracapsular hip fractures in adults.

Martyn J Parker, Avishek Das

Open access · bronzeAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed, 1 pooled it
5.2field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 1 synthesis or guideline pooled it, 62 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Trial
  4. Review
  5. Article
  6. Article
  7. Outcome of unstable pertrochanteric fractures in high-risk geriatric treated with external fixators.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2022
    Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Extramedullary fixation of trochanteric hip fracture.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2014
    Article
  16. Outcomes after trifocal femoral fractures.Case reports in surgery · 2014
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

2 authors at 2 institutions in 1 country.

Martyn J ParkerDepartment of Orthopaedics, Peterborough and Stamford Hospitals NHS Foundation Trust, Peterborough, UK. martyn.parker@pbh-tr.nhs.uk.
Avishek Das
Peterborough and Stamford Hospitals NHS Foundation Trust · GBPeterborough City Hospital · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundExtramedullary fixation of hip fractures involves the application of a plate and screws to the lateral side of the proximal femur. In external fixators, the stabilising component is held outside the thigh by pins or screws driven into the bone. This is an update of a Cochrane review first published in 1998, and last updated in 2005.

objectivesTo assess the relative effects of different types of extramedullary fixation implant, as well as external fixators, for treating extracapsular proximal femoral (hip) fractures in adults. SEARCH

methodsWe searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register (July 2011), the Cochrane Central Register of Controlled Trials (The Cochrane Library 2011, Issue 2), MEDLINE (1966 to June Week 4 2011), EMBASE (1988 to 2011 Week 25), various other databases, conference proceedings and reference lists. SELECTION CRITERIA: Randomised or quasi-randomised controlled trials comparing extramedullary implants or external fixators for fixing extracapsular hip fracture in adults were included. DATA COLLECTION AND ANALYSIS: Two review authors independently selected trials, assessed risk of bias and extracted data. Data were pooled where appropriate. MAIN

resultsThe 18 included trials tested seven comparisons in a total of 2615 mainly female and older participants with a total of 2619 fractures. All trials had methodological flaws that may affect the validity of their results.Three trials of 355 participants comparing a fixed nail plate (Jewett or McLaughlin) with the sliding hip screw (SHS) found an increased risk of fixation failure for fixed nail plates.The two trials of 433 participants comparing the Resistance Augmented Bateaux (RAB) plate with the SHS had contrasting results, notably in terms of operative complications, fixation failure and anatomical restoration.One trial of 100 participants comparing the Pugh nail and the SHS found no significant difference between implants.Three trials of 458 participants compared the Medoff plate with the SHS. There was a trend to higher blood losses and longer operation times for the Medoff plate along with a trend to a lower risk of fixation failure with the Medoff plate for unstable trochanteric fractures.Two trials of 676 participants compared the Medoff plate with three different screw-plate systems. There were no statistically significant differences in outcome for trochanteric fractures. For subtrochanteric fractures, there was a lower fixation failure rate for the Medoff plate but no evidence for differences in longer-term outcomes.Four trials of 396 participants comparing the Gotfried percutaneous compression plate (PCCP) with a SHS found a trend to lower blood loss and transfusion requirements for the PCCP but no other confirmed differences in outcomes between implants. Three of the trials reported intra-operative problems with the PCCP, some of which precluded its use.Three trials of 200 participants comparing external fixation with a SHS found less operative trauma for the external fixation. Final outcome appeared similar. AUTHORS'

conclusionsThe markedly increased fixation failure rate of fixed nail plates compared with the SHS is a major consideration and thus the SHS appears preferable.There was insufficient evidence from other comparisons of extramedullary implants or on the use of external fixators to draw definite conclusions.

Indexed as

Bone NailsBone PlatesBone ScrewsAgedAged, 80 and overFemaleFracture FixationHip FracturesHumansMaleRandomized Controlled Trials as Topic

Identifiers

PMID23450528
PMCPMC7061252
OpenAlexW1960542948

What OpenQuestion holds

Textmetadata
Read underepoch 390