ArticleClinical ophthalmology (Auckland, N.Z.)2013

Transition to a novel advanced integrated vitrectomy platform: comparison of the surgical impact of moving from the Accurus vitrectomy platform to the Constellation Vision System for microincisional vitrectomy surgery.

Timothy G Murray, Andrew J Layton, Kuo B Tong, Michael Gittelman, Azeema Latiff, Daniel Gologorsky, Michael M Vigoda

Open access · goldAbstract read
In one paragraph

Article in Clinical ophthalmology (Auckland, N.Z.), 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Timothy G MurrayMurray Ocular Oncology and Retina, Miami, FL, USA ; Bascom Palmer Eye Institute, Anne Bates Leach Eye Hospital, Departments of Ophthalmology, Anesthesiology and Radiation Oncology, University of Miami Miller School of Medicine, Miami, FL, USA.
Andrew J Layton
Kuo B Tong
Michael Gittelman
Azeema Latiff
Daniel Gologorsky
Michael M Vigoda
University of Miami · USHe Eye Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMicroincisional vitrectomy surgery (MIVS) is the current standard surgical approach for pars plana vitrectomy. Historically, the most common surgical platform for vitrectomy surgery, since its introduction in 1997, has been the Accurus vitrectomy system. Recent introduction of the next generation of vitrectomy platforms has generated concerns associated with transitioning to new technology in the operating room environment. This study compared, in a matched fashion, surgical use of the Accurus vitrectomy system and the next generation Constellation Vision System to evaluate surgical efficiencies, complications, and user perceptions of this transition.

methodsElectronic health records were abstracted as a hospital quality assurance activity and included all vitreoretinal surgical procedures at the Bascom Palmer Eye Institute, Anne Bates Leach Eye Hospital, during two discrete 12-month time periods. These two periods reflected dedicated usage of the Accurus (June 2008-May 2009) and Constellation Vision (July 2009-June 2010) systems. Data were limited to a single surgeon and evaluated for operating room (OR) total time usage/day, OR case time/case, and OR surgical time/case. Further analysis evaluated all patients undergoing combined MIVS and clear cornea phacoemulsification/intraocular lens (IOL) implantation during each individual time period to determine the impact of the instrumentation on these parameters. All records were evaluated for intraoperative complications.

resultsFive hundred and fourteen eligible patients underwent MIVS during the 2-year study windows, with 281 patients undergoing surgery with the Accurus system and 233 patients undergoing surgery with the Constellation system. Combined MIVS and phacoemulsification with IOL implantation was performed 141 times during this period with the Accurus and 158 times during the second study period with the Constellation. Total number of patients operated per day increased from 7.55 with Accurus to 8.53 with Constellation. Surgical room time decreased from 56 minutes with Accurus to 52 minutes with Constellation, and procedure time decreased from 35 minutes with Accurus to 31 minutes with Constellation (P < 0.004). Combined MIVS/phacoemulsification surgery saw similar declines in surgical room time and procedure time (P < 0.001). Subset analysis of procedures limited by case number per day (eg, four cases/day, five cases/day, six cases/day, and seven or more cases/day) showed similar outcomes with a decrease in surgical room time and procedure time. No increases in surgery-related complications were noted by quality assurance review during these time periods. DISCUSSION: Transitioning to advanced surgical technology is a complex issue for the surgeon, the hospital team, and the hospital administration. This study documents improvement in three significant measures of surgical efficiency: operative number of patients per day, operative room time, and surgical procedure time that reflect the positive impact of the novel, combined, integrated, posterior and anterior, ophthalmologic surgical platform of the Constellation Vision System. These data are imperative to evaluate the impact of transition from one surgical platform to another. During this transition, hospital quality assurance review and surgeon evaluation of operative complications showed no increased concerns for the shift from the Accurus to the Constellation Vision System surgical platform. Further, both operative staff and surgeons felt that the transition to the Constellation was not associated with increases in difficulty with setup, turnover, or use and that the Constellation decreased safety concerns for surgical usage. Ultimately, in this case, new technology benefited the surgeon, the patient, and the hospital.

Indexed as

MIVSnew technologyvitrectomy