Performance evaluation of LUMIPULSE G1200 autoimmunoanalyzer for the detection of serum hepatitis B virus markers.
Article in Journal of clinical laboratory analysis, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- Analytical performance evaluation of MAGLUMI HBeAg and anti-HBe chemiluminescence immunoassays and comparison with the Abbott assays.Frontiers in cellular and infection microbiology · 2026Article
- Clinical Significance and Remaining Issues of Anti-HBc Antibody and HBV Core-Related Antigen.Diagnostics (Basel, Switzerland) · 2024Review
- Analysis of hepatitis B and C virus infections amongst members of the Dental National Health Insurance Society in the Oita Prefecture.Biomedical reports · 2021Article
- Clinical features of chronic hepatitis B patients with low hepatitis B surface antigen levels and determinants of hepatitis B surface antigen seroclearance.JGH open : an open access journal of gastroenterology and hepatology · 2020Article
- Evaluation of the clinical performance of the HISCL-5000 analyzer in the detection of Krebs von den Lungen-6 antigen and its diagnostic value in interstitial lung disease.Journal of clinical laboratory analysis · 2020Article
- Review
- Evaluation of the highly sensitive chemiluminescent enzyme immunoassay "Lumipulse HBsAg-HQ" for hepatitis B virus screening.Journal of clinical laboratory analysis · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundWe evaluated recently introduced automated immunoassay analyzer LUMIPULSE G1200 (Fujirebio, Inc., Tokyo, Japan) for detecting serologic hepatitis B virus (HBV) markers by comparison with the results by ARCHITECT i4000SR (Abbott, Abbott Park, IL).
methodsPrecision performance was evaluated over 20 days. HBV surface antigen (HBsAg), HBV e antigen (HBeAg), antibodies to HBV core antigen (anti-HBc), antibodies to HBeAg (anti-HBe), and antibodies to HBsAg (anti-HBs) in a total of 1,000 serum samples were assessed by the two analyzers. Discrepant results were retested by COBAS e411 (Roche Diagnostics, Mannheim, Germany).
resultsLUMIPULSE showed excellent precision performance of total imprecision less than 3.5% coefficient of variation. The qualitative results between the two analyzers were agreed with each other in 92.0-99.8% of the specimens according to the different HBV markers. The degrees of reactions for HBeAg were moderately correlated between the two analyzers (r = 0.60), and those of other HBV markers were well correlated (r = 0.80 or greater). However, there were 183 discrepancies among 1,000 cases, and most of them showed degree of reaction around the cutoff values.
conclusionsLUMIPULSE G1200 showed well-concordant results with ARCITHECT for hepatitis B serologic tests. However, results near the cutoff values would need to be retested with other immunoassay or molecular methods, when the serological profiles of HBV markers are unusual or are not correlated to the clinical conditions of the patient, due to discrepancies between the immunoassay analyzers.