Trial reportJournal of diabetes science and technology2013
First clinical evaluation of a new percutaneous optical fiber glucose sensor for continuous glucose monitoring in diabetes.
Trial report in Journal of diabetes science and technology, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 32 citations in OpenAlex.
- Towards Standardization of CGM Performance Studies: The QUSS-CGM Questionnaire for Assessing User Satisfaction.Patient related outcome measures · 2025Article
- Performance Assessment of Three Continuous Glucose Monitoring Systems in Adults With Type 1 Diabetes.Journal of diabetes science and technology · 2024Article
- Insertable Glucose Sensor Using a Compact and Cost-Effective Phosphorescence Lifetime Imager and Machine Learning.ACS nano · 2024Article
- Clinical Performance Evaluation of Continuous Glucose Monitoring Systems: A Scoping Review and Recommendations for Reporting.Journal of diabetes science and technology · 2023Article
- Review
- Polymer Optical Fiber Tip Mass Production Etch Mechanism to Achieve CPC Shape for Improved Biosensor Performance.Sensors (Basel, Switzerland) · 2019Article
- Micro-Electromechanical Affinity Sensor for the Monitoring of Glucose in Bioprocess Media.International journal of molecular sciences · 2017Article
- High Affinity Mannotetraose as an Alternative to Dextran in ConA Based Fluorescent Affinity Glucose Assay Due to Improved FRET Efficiency.ACS sensors · 2016Article
- Performance assessment of a closed-loop system for diabetes management.Medical & biological engineering & computing · 2015Article
- Advancing the development of glycated protein biosensing technology: next-generation sensing molecules.Journal of diabetes science and technology · 2015Review
- Thirty-fifth anniversary of the optical affinity sensor for glucose: a personal retrospective.Journal of diabetes science and technology · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThis article describes a new fiber-coupled, percutaneous fluorescent continuous glucose monitoring (CGM) system that has shown 14 days of functionality in a human clinical trial.
methodThe new optical CGM system (FiberSense) consists of a transdermal polymer optical fiber containing a biochemical glucose sensor and a small fluorescence photometer optically coupled to the fiber. The glucose-sensitive optical fiber was implanted in abdominal and upper-arm subcutaneous tissue of six diabetes patients and remained there for up to 14 days. The performance of the system was monitored during six visits to the study center during the trial. Blood glucose changes were induced by oral carbohydrate intake and insulin injections, and capillary blood glucose samples were obtained from the finger tip. The data were analyzed using linear regression and the consensus error grid analysis.
resultsThe FiberSense worn at the upper arm exhibited excellent results during 14 wearing days, with an overall mean absolute relative difference (MARD) of 8.3% and 94.6% of the data in zone A of the consensus error grid. At the abdominal application site, FiberSense resulted in a MARD of 11.4 %, with 93.8% of the data in zone A.
conclusionsThe FiberSense CGM system provided consistent, reliable measurements of subcutaneous glucose levels in human clinical trial patients with diabetes for up to 14 days.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials