ArticleJournal of biomedical materials research. Part B, Applied biomaterials2013
Characteristics of highly cross-linked polyethylene wear debris in vivo.
Article in Journal of biomedical materials research. Part B, Applied biomaterials, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 42 citations in OpenAlex.
- Soft, Reactive, and Alive: A Dynamic Framework for Degradation and Functional Stability of Polymeric Biomaterials.Polymers · 2026Review
- Roles of inflammatory cell infiltrate in periprosthetic osteolysis.Frontiers in immunology · 2023Review
- Quantitative Measurements of Backside Wear in Acetabular Hip Joint Replacement: Conventional Polyethylene Versus Cross-Linked Polyethylene.Materials (Basel, Switzerland) · 2020Article
- Periprosthetic Osteolysis: Mechanisms, Prevention and Treatment.Journal of clinical medicine · 2019Review
- Peri-Implant Distribution of Polyethylene Debris in Postmortem-Retrieved Knee Arthroplasties: Can Polyethylene Debris Explain Loss of Cement-Bone Interlock in Successful Total Knee Arthroplasties?The Journal of arthroplasty · 2017Article
- UHMWPE wear debris and tissue reactions are reduced for contemporary designs of lumbar total disc replacements.Clinical orthopaedics and related research · 2015Article
- How has the introduction of new bearing surfaces altered the biological reactions to byproducts of wear and modularity?Clinical orthopaedics and related research · 2014Review
- The role of oxidative stress in aseptic loosening of total hip arthroplasties.The Journal of arthroplasty · 2014Article
- Innate immunity sensors participating in pathophysiology of joint diseases: a brief overview.Journal of long-term effects of medical implants · 2014Article
- Severe impingement of lumbar disc replacements increases the functional biological activity of polyethylene wear debris.The Journal of bone and joint surgery. American volume · 2013Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
Abstract
Despite the widespread implementation of highly cross-linked polyethylene (HXLPE) liners to reduce the clinical incidence of osteolysis, it is not known if the improved wear resistance will outweigh the inflammatory potential of HXLPE wear debris generated in vivo. Thus, we asked: What are the differences in size, shape, number, and biological activity of polyethylene wear particles obtained from primary total hip arthroplasty revision surgery of conventional polyethylene (CPE) versus remelted or annealed HXLPE liners? Pseudocapsular tissue samples were collected from revision surgery of CPE and HXLPE (annealed and remelted) liners, and digested using nitric acid. The isolated polyethylene wear particles were evaluated using scanning electron microscopy. Tissues from both HXLPE cohorts contained an increased percentage of submicron particles compared to the CPE cohort. However, the total number of particles was lower for both HXLPE cohorts, as a result there was no significant difference in the volume fraction distribution and specific biological activity (SBA; the relative biological activity per unit volume) between cohorts. In contrast, based on the decreased size and number of HXLPE wear debris there was a significant decrease in total particle volume (mm(3)/g of tissue). Accordingly, when the SBA was normalized by total particle volume (mm(3)/gm tissue) or by component wear volume rate (mm(3)/year), functional biological activity of the HXLPE wear debris was significantly decreased compared to the CPE cohort. Indications for this study are that the osteolytic potential of wear debris generated by HXLPE liners in vivo is significantly reduced by improvements in polyethylene wear resistance.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.