Evidence map›Paper›PMID 23436587›Full record

ArticleJournal of biomedical materials research. Part B, Applied biomaterials2013

Characteristics of highly cross-linked polyethylene wear debris in vivo.

Ryan M Baxter, Daniel W MacDonald, Steven M Kurtz, Marla J Steinbeck

Open access · greenAbstract read
In one paragraph

Article in Journal of biomedical materials research. Part B, Applied biomaterials, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
5.2field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 42 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Review
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Ryan M BaxterSchool of Biomedical Engineering, Science & Health Systems, Drexel University, Philadelphia, Pennsylvania, USA.
Daniel W MacDonald
Steven M Kurtz
Marla J Steinbeck
Drexel University · USExponent (United States) · US

Funding

MECHANISMS &PERFORMANCE OF TRACEABLE UHMWPE IMPLANTSR01AR047904 · NIAMS · DREXEL UNIVERSITY · PI KURTZ, STEVEN MICHAEL · 2001 to 2015
$6.1M
NIAMS NIH HHS R01 AR047904NIAMS NIH HHS R01 AR47904
6 · The paper itself

Abstract

Despite the widespread implementation of highly cross-linked polyethylene (HXLPE) liners to reduce the clinical incidence of osteolysis, it is not known if the improved wear resistance will outweigh the inflammatory potential of HXLPE wear debris generated in vivo. Thus, we asked: What are the differences in size, shape, number, and biological activity of polyethylene wear particles obtained from primary total hip arthroplasty revision surgery of conventional polyethylene (CPE) versus remelted or annealed HXLPE liners? Pseudocapsular tissue samples were collected from revision surgery of CPE and HXLPE (annealed and remelted) liners, and digested using nitric acid. The isolated polyethylene wear particles were evaluated using scanning electron microscopy. Tissues from both HXLPE cohorts contained an increased percentage of submicron particles compared to the CPE cohort. However, the total number of particles was lower for both HXLPE cohorts, as a result there was no significant difference in the volume fraction distribution and specific biological activity (SBA; the relative biological activity per unit volume) between cohorts. In contrast, based on the decreased size and number of HXLPE wear debris there was a significant decrease in total particle volume (mm(3)/g of tissue). Accordingly, when the SBA was normalized by total particle volume (mm(3)/gm tissue) or by component wear volume rate (mm(3)/year), functional biological activity of the HXLPE wear debris was significantly decreased compared to the CPE cohort. Indications for this study are that the osteolytic potential of wear debris generated by HXLPE liners in vivo is significantly reduced by improvements in polyethylene wear resistance.

Indexed as

Arthroplasty, Replacement, HipMaterials TestingPolyethyleneAgedFemaleHumansMaleMiddle AgedPolyethylene