Evidence map›Paper›PMID 23433462›Full record

Trial reportScandinavian journal of trauma, resuscitation and emergency medicine2013

Evaluation of airway management associated hands-off time during cardiopulmonary resuscitation: a randomised manikin follow-up study.

Christina Gruber, Sabine Nabecker, Philipp Wohlfarth, Anita Ruetzler, Dominik Roth, Oliver Kimberger, Henrik Fischer, Michael Frass, Kurt Ruetzler

Open access · goldAbstract readRandomized Controlled Trial
In one paragraph

Trial report in Scandinavian journal of trauma, resuscitation and emergency medicine, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
3.7field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 32 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Trial
  4. Trial
  5. Article
  6. Article
  7. Article
  8. Observational
  9. Article
  10. Review
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Christina GruberDepartment of General Anaesthesia and Intensive Care, Medical University of Vienna, Vienna, Austria.
Sabine Nabecker
Philipp Wohlfarth
Anita Ruetzler
Dominik Roth
Oliver Kimberger
Henrik Fischer
Michael Frass
Kurt Ruetzler
Medical University of Vienna · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionAirway management is an important component of cardiopulmonary resuscitation (CPR). Recent guidelines recommend keeping any interruptions of chest compressions as short as possible and not lasting more than 10 seconds. Endotracheal intubation seems to be the ideal method for establishing a secure airway by experienced providers, but emergency medical technicians (EMT) often lack training and practice. For the EMTs supraglottic devices might serve as alternatives.

methods40 EMTs were trained in a 1-hour standardised audio-visual lesson to handle six different airway devices including endotracheal intubation, Combitube, EasyTube, I-Gel, Laryngeal Mask Airway and Laryngeal tube. EMTs performances were evaluated immediately after a brief practical demonstration, as well as after 1 and 3 months without any practice in between, in a randomised order. Hands-off time was pair-wise compared between airway devices using a repeated-measures mixed-effects model.

resultsOverall mean hands-off time was significantly (p<0.01) lower for Laryngeal tube (6.1s; confidence interval 5.2-6.9s), Combitube (7.9s; 95% CI 6.9-9.0s), EasyTube (8.8s; CI 7.3-10.3s), LMA (10.2s; CI 8.6-11.7s), and I-Gel (11.9s; CI 10.2-13.7s) compared to endotracheal intubation (39.4s; CI 34.0-44.9s). Hands-off time was within the recommended limit of 10s for Combitube, EasyTube and Laryngeal tube after 1 month and for all supraglottic devices after 3 months without any training, but far beyond recommended limits in all three evaluations for endotracheal intubation.

conclusionUsing supraglottic airway devices, EMTs achieved a hands-off time within the recommended time limit of 10s, even after three months without any training or practice. Supraglottic airway devices are recommended tools for EMTs with lack of experience in advanced airway management.

Indexed as

ManikinsAdultAirway ExtubationAirway ManagementAudiovisual AidsCardiopulmonary ResuscitationConfidence IntervalsEmergency Medical TechniciansFemaleFollow-Up StudiesHumansMaleYoung Adult

Identifiers

PMID23433462
PMCPMC3598524
OpenAlexW2069107300

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.