Evidence map›Paper›PMID 23420191›Full record

ArticleBiomedical microdevices2013

A microfluidic immunomagnetic bead-based system for the rapid detection of influenza infections: from purified virus particles to clinical specimens.

Lien-Yu Hung, Tze-Bin Huang, Yi-Che Tsai, Chen-Sheng Yeh, Huan-Yao Lei, Gwo-Bin Lee

Abstract read
In one paragraph

Article in Biomedical microdevices, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. On-Chip Optical Detection of Viruses: A Review.Advanced photonics research · 2021
    Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Lien-Yu HungDepartment of Power Mechanical Engineering, National Tsing Hua University, Hsinchu, Taiwan, 30013.
Tze-Bin Huang
Yi-Che Tsai
Chen-Sheng Yeh
Huan-Yao Lei
Gwo-Bin Lee

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Seasonal and novel influenza infections have the potential to cause worldwide pandemics. In order to properly treat infected patients and to limit its spread, a rapid, accurate and automatic influenza diagnostic tool needs to be developed. This study therefore presents a new integrated microfluidic system for the rapid detection of influenza infections. It integrated a suction-type, pneumatic-driven microfluidic control module, a magnetic bead-based fluorescent immunoassay (FIA) and an end-point optical detection module. This new system can successfully distinguish between influenza A and B using a single chip test within 15 min automatically, which is faster than existing devices. By utilizing the micromixers to thoroughly wash out the sputum-like mucus, this microfluidic system could be used for the diagnosis of clinical specimens and reduced the required sample volume to 40 μL. Furthermore, the results of diagnostic assays from 86 patient specimens have demonstrated that this system has 84.8 % sensitivity and 75.0 % specificity. This developed system may provide a powerful platform for the fast screening of influenza infections.

Indexed as

MicrospheresAntibodies, MonoclonalHumansImmunoassayInfluenza A virusInfluenza A Virus, H1N1 SubtypeInfluenza A Virus, H3N2 SubtypeInfluenza, HumanLimit of DetectionMagnetsMicrofluidic Analytical TechniquesTime FactorsVirionAntibodies, Monoclonal

Identifiers

PMID23420191
PMCPMC7087985

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.