ArticleExperimental and therapeutic medicine2013
Development and validation of a HPLC-MS/MS method with electrospray ionization for quantitation of potassium oxonate in human plasma: Application to a pharmacokinetic study.
Article in Experimental and therapeutic medicine, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A rapid, sensitive and specific HPLC-MS/MS method was developed and validated for the quantification of potassium oxonate (Oxo) in human plasma using [(13)C(2),(15)N(3)]-Oxo as an internal standard (IS). The target substance was separated from human plasma using the solid-phase extraction method. Chromatography separation was performed on a Waters:Atlantis dC(18) column (150×4.6 mm, 5.0 μm) with a mobile phase consisting of H(2)O with 0.1% formic acid in acetonitrile (90:10, v/v). The mass spectrometer works with electrospray ionization and multiple reaction monitoring in its negative ion mode, using target ions at [M-H](-) m/z 111.9 for Oxo and [M-H](-) m/z 117.0 for the IS. The mean standard curve was linear (r=0.9991) over the concentration range of 2.0-200.0 ng/ml and had good back-calculated accuracy and precision. The intra- and inter-day precision were <6.33% and the accuracy was >99.38%. The extraction recovery was >60.26%. The lower limit of quantification achieved with this method was 2.0 ng/ml. This assay method was demonstrated to be accurate, sensitive and simple and was successfully applied to a pharmacokinetic study following single oral administration of a 40-mg S-1 capsule in 12 tumor patients.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.