Evidence map›Paper›PMID 23402692›Full record

ArticleThe Journal of thoracic and cardiovascular surgery2013

Use of a low-resistance compliant thoracic artificial lung in the pulmonary artery to pulmonary artery configuration.

Christopher N Scipione, Rebecca E Schewe, Kelly L Koch, Andrew W Shaffer, Amit Iyengar, Keith E Cook

Open access · bronzeAbstract read
In one paragraph

Article in The Journal of thoracic and cardiovascular surgery, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.5field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 12 citations in OpenAlex.

  1. Bioengineering Progress in Lung Assist Devices.Bioengineering (Basel, Switzerland) · 2021
    Review
  2. A Model of Pediatric End-Stage Lung Failure in Small Lambs <20 kg.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2020
    Article
  3. Low-Resistance, Concentric-Gated Pediatric Artificial Lung for End-Stage Lung Failure.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2020
    Article
  4. Early in vivo experience with the pediatric continuous-flow total artificial heart.The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2018
    Article
  5. Fourteen Day In Vivo Testing of a Compliant Thoracic Artificial Lung.ASAIO journal (American Society for Artificial Internal Organs : 1992)
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Christopher N ScipioneDepartment of General Surgery, University of Michigan Medical Center, Ann Arbor, Mich, USA.
Rebecca E Schewe
Kelly L Koch
Andrew W Shaffer
Amit Iyengar
Keith E Cook
University of Michigan–Ann Arbor · US

Funding

Compliant Thoracic Artificial LungsR01HL089043 · NHLBI · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI COOK, KEITH E · 2009 to 2017
$4.2M
NHLBI NIH HHS R01 HL089043
6 · The paper itself

Abstract

backgroundThoracic artificial lungs have been proposed as a bridge to transplant in patients with end-stage lung disease. Systemic embolic complications can occur after thoracic artificial lung attachment in the pulmonary artery to left atrium configuration. Therefore, we evaluated the function of a compliant thoracic artificial lung attached via the proximal pulmonary artery to distal main pulmonary artery configuration.

methodsThe compliant thoracic artificial lung was attached to 5 sheep (63 ± 0.9 kg) in the proximal pulmonary artery to distal main pulmonary artery configuration. Device function and animal hemodynamics were assessed at baseline and with approximately 60%, 75%, and 90% of cardiac output diverted to the compliant thoracic artificial lung. At each condition, dobutamine (0 and 5 μg·kg(-1)·min(-1)) was used to simulate rest and exercise conditions.

resultsAt rest, cardiac output decreased from 6.20 ± 0.53 L/min at baseline to 5.40 ± 0.43, 4.66 ± 0.31, and 4.05 ± 0.27 L/min with 60%, 75%, and 90% of cardiac output to the compliant thoracic artificial lung, respectively (P < .01 for each flow diversion vs baseline). During exercise, cardiac output decreased from 7.85 ± 0.70 L/min at baseline to 7.46 ± 0.55, 6.93 ± 0.51, and 5.96 ± 0.44 L/min (P = .82, P = .19, and P < .01 with respect to baseline) with 60%, 75%, and 90% of cardiac output to the compliant thoracic artificial lung, respectively. The artificial lung resistance averaged 0.46 ± 0.02 and did not vary significantly with blood flow rate.

conclusionsUse of a compliant thoracic artificial lung may be feasible in the proximal pulmonary artery to distal main pulmonary artery setting if its blood flow is held at less than 75% of cardiac output. To ensure a decrease in cardiac output of less than 10%, a blood flow rate less than 60% of cardiac output is advised.

Indexed as

Artificial OrgansAnimalsArterial PressureCardiac OutputCentral Venous PressureExtracorporeal Membrane OxygenationHemodynamicsLungLung ComplianceLung TransplantationMalePhysical Conditioning, AnimalPulmonary ArteryRestSheepThoracotomy

Identifiers

PMID23402692
PMCPMC3653992
OpenAlexW2071909368

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.