ArticleEuropean journal of applied physiology2013
Effects of wind application on thermal perception and self-paced performance.
Article in European journal of applied physiology, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Effects of Precooling on Endurance Exercise Performance in the Heat: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.Nutrients · 2024Pooled it
- Value driven co-design of smart sportswear for heat illness prevention in tropical regions.Frontiers in digital health · 2026Article
- The Type of Per-Cooling Strategies Currently Employed by Competitive and Professional Cyclists-Triathletes During Training and Competition Are Condition (Dry vs. Humid) Dependant.Frontiers in sports and active living · 2022Article
- In the Subtropical Monsoon Climate High-Density City, What Features of the Neighborhood Environment Matter Most for Public Health?International journal of environmental research and public health · 2020Article
- Per-Cooling (Using Cooling Systems during Physical Exercise) Enhances Physical and Cognitive Performances in Hot Environments. A Narrative Review.International journal of environmental research and public health · 2020Review
- Fan cooling after cardiovascular drift does not reverse decrements in maximal oxygen uptake during heat stress.Temperature (Austin, Tex.) · 2019Article
- Skin Temperature Measurement Using Contact Thermometry: A Systematic Review of Setup Variables and Their Effects on Measured Values.Frontiers in physiology · 2018Review
- Cooling During Exercise: An Overlooked Strategy for Enhancing Endurance Performance in the Heat.Sports medicine (Auckland, N.Z.) · 2017Review
- Cooling interventions for athletes: An overview of effectiveness, physiological mechanisms, and practical considerations.Temperature (Austin, Tex.) · 2017Review
- Effects of solar radiation on endurance exercise capacity in a hot environment.European journal of applied physiology · 2016Article
- Effect of Environmental and Feedback Interventions on Pacing Profiles in Cycling: A Meta-Analysis.Frontiers in physiology · 2016Review
- Ingestion of a cold temperature/menthol beverage increases outdoor exercise performance in a hot, humid environment.PloS one · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Physiological and perceptual effects of wind cooling are often intertwined and have scarcely been studied in self-paced exercise. Therefore, we aimed to investigate (1) the independent perceptual effect of wind cooling and its impact on performance and (2) the responses to temporary wind cooling during self-paced exercise. Ten male subjects completed four trials involving 15 min standardized incremental intensity cycling, followed by a 15-km self-paced cycling time trial. Three trials were performed in different climates inducing equivalent thermal strain: hot humid with wind (WIND) and warm humid (HUMID) and hot dry (DRY) without wind. The fourth trial (W3-12) was equal to HUMID, except that wind cooling was unexpectedly provided during kilometers 3-12. Physiological, perceptual and performance parameters were measured. Subjects felt generally cooler during the WIND than the HUMID and DRY trials, despite similar heart rate, rectal and skin temperatures and a WBGT of ~4 °C higher. The cooler thermal sensation was not reflected in differences in thermal comfort or performance. Comparing W3-12 to HUMID, skin temperature was 1.47 ± 0.43 °C lower during the wind interval, leading to more favorable ratings of perceived exertion, thermal sensation and thermal comfort. Overall, power output was higher in the W3-12 than the HUMID-trial (256 ± 29 vs. 246 ± 22 W), leading to a 67 ± 48 s faster finish time. In conclusion, during self-paced exercise in the heat, wind provides immediate and constant benefits in physiological strain, thermal perception and performance. Independent of physiological changes, wind still provides a greater sensation of coolness, but does not impact thermal comfort or performance.
Indexed as
Identifiers
23385657What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.