Evidence map›Paper›PMID 23361128›Full record

Observational studyJournal of clinical monitoring and computing2013

Cardiac output monitoring in septic shock: evaluation of the third-generation Flotrac-Vigileo.

Sophie Marqué, Antoine Gros, Loic Chimot, Arnaud Gacouin, Sylvain Lavoué, Christophe Camus, Yves Le Tulzo

Registry-linked trialAbstract readComparative StudyEvaluation StudyObservational Study
PubMed Publisher
In one paragraph

Observational study in Journal of clinical monitoring and computing, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02565251 (Volemic Resuscitation in Sepsis and Septic Shock), which is not on this map. Cited by 15 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed, 1 pooled it
4.1field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT02565251 naunknown statusnot on this mapstarted 2015, after this paper: background citation

Volemic Resuscitation in Sepsis and Septic Shock

TypeinterventionalSponsorIuliu Hatieganu University of Medicine and PharmacyRan2015 to 2017Enrolled100ConditionsHemodynamic Instability, Sepsis, Septic ShockArmsFlotrac/Ev1000, Standard ICU monitorisation, VolumeView/Ev1000
3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 1 synthesis or guideline pooled it, 31 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Review
  12. Article
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Sophie MarquéService de Réanimation Médico-Chirurgicale, Centre Hospitalier Sud Francilien, 116 boulevard Jean Jaurès, 91106 Corbeil Essonnes, France. sophie.marque@ch-sud-francilien.fr
Antoine Gros
Loic Chimot
Arnaud Gacouin
Sylvain Lavoué
Christophe Camus
Yves Le Tulzo
Centre Hospitalier Universitaire de Rennes · FRCentre Hospitalier de Versailles · FRCentre Hospitalier Sud Francilien · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Continuous cardiac index (CI) monitoring is frequently used in critically ill patients. Few studies have compared the pulse contour-based device FloTrac/Vigileo to pulmonary artery thermodilution (PAC) in terms of accuracy for CI monitoring in septic shock. The aim of our study was to compare the third-generation FloTrac/Vigileo to PAC in septic shock. Eighteen patients with septic shock requiring monitoring by PAC were included in this study. We monitored CI using both FloTrac/Vigileo and continuous thermodilution (PAC-CI). Hemodynamic data were recorded every hour or every 2 min during fluid challenges. The primary endpoint was the global agreement of all CI-paired measurements determined using the Bland-Altman method adapted to replicated data. We tested the linearity of the bias by regression analysis, and compared the reactivity of the 2 techniques during fluid challenges. A receiver operating characteristic (ROC) curve analysis tested the ability of FloTrac/Vigileo to detect concordant and significative CI changes, using PAC-CI as the reference method. Overall, 1,201 paired CI measurements were recorded. The Bland-Altman analysis for global agreement of the 2 techniques showed a bias of -0.1 ± 2.1 L min(-1) m(-2) and a percentage error of 64 %. The overall correlation coefficient between PAC-CI and FloTrac/Vigileo CI was 0.47 (p < 0.01), with r(2) = 0.22. The area under the curve of the ROC curve for detecting concordant and significant changes in CI was 0.72 (0.53; 0.87). In our study, third-generation Flowtrac-Vigileo appears to be too inaccurate to be recommended for CI monitoring in septic shock.

Indexed as

Cardiac OutputAdultAgedAged, 80 and overCritical IllnessFemaleHumansMaleMiddle AgedMonitoring, PhysiologicProspective StudiesPulmonary ArteryShock, SepticSoftwareThermodilution

Identifiers

PMID23361128
OpenAlexW2074737552

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.