ArticleInternational journal of surgery case reports2013
Small bowel lesion due to spiral tacks after laparoscopic intraperitoneal onlay mesh repair for incisional hernia.
Article in International journal of surgery case reports, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 24 citations in OpenAlex.
- Comparative analysis of efficacy and quality of life between totally extraperitoneal sublay and intraperitoneal onlay mesh repair for ventral hernia.Scientific reports · 2025Article
- Article
- Laparoscopic Intraperitoneal Onlay Mesh (IPOM) in the Treatment of Ventral Hernias: Technique Discussion Points.Cureus · 2024Review
- Tentacle Mesh for Fixation-Free Spigelian Hernia Repair: Mini-Invasive Approach Granting Broad Defect Overlap.Journal of clinical medicine · 2023Article
- Initial results of an indigenous absorbable tacker for mesh fixation in laparoscopic ventral hernia repair: a retrospective analysis of 158 cases.Hernia : the journal of hernias and abdominal wall surgery · 2022Article
- Fixation free laparoscopic obliteration of inguinal hernia defects with the 3D dynamic responsive scaffold ProFlor.Scientific reports · 2022Article
- Acute colonic pseudo-obstruction and rapid septic progression after transabdominal preperitoneal hernia repair: a case report.BMC surgery · 2021Article
- Mesh fixation using novel bio-adhesive coating compared to tack fixation for IPOM hernia repair: in vivo evaluation in a porcine model.Surgical endoscopy · 2019Article
- Modified laparoscopic Sugarbaker repair of parastomal hernia with a three-point anchoring technique.World journal of clinical cases · 2018Article
- Use of Nonabsorbable Spiral Tacks for Mesh Reinforcement in Thoracoscopic Repair of Congenital Diaphragmatic Hernia.European journal of pediatric surgery reports · 2018Article
- Unusual complication of seroma after ventral hernia mesh repair: Digestive perforation by tacks. A case report.International journal of surgery case reports · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionLaparoscopic intraperitoneal onlay mesh (IPOM) repair has become a widely accepted operative technique for incisional hernias. However, tack fixation poses the risk of adhesions and injury to the intestine. We report the case of spiral tacks adherent to the small bowel after IPOM repair for incisional hernia. PRESENTATION OF CASE: 64 years old male patient who underwent laparoscopic IPOM repair for incisional hernia 1 year after open sigmoid resection. A laminated polypropylene mesh was fixed with titanium spiral tacks. 4 years later, elective open cholecystectomy was performed. Two spiral tacks integrated in the seromusular layer of the small bowel were encountered. Tacks were removed and bowel lesions oversewn with interrupted seromuscular stitches. DISCUSSION: According to the current literature, complications related to metal spiral tacks in IPOM mesh repair such as intestinal perforation or strangulation ileus seem to be rare. To our knowledge, spiral tacks adherent to the intestine have not yet been published to date. Alternative techniques for mesh fixation are transfascial sutures with single stitches, continuous sutures or fibrin glue, as already used in TAPP and TEP procedures for inguinal hernia repair. The ideal and safest technique for mesh fixation in IPOM repair for incisional hernias remains controversial.
conclusionSpiral tacks used for intraperitoneal mesh fixation can lead to adhesions and bowel lesions. Sutures, absorbable tacks or fibrin glue are alternatives for mesh fixation. Further clinical trials are needed to evaluate the safest technique of laparoscopic IPOM incisional hernia repair.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.