Evidence map›Paper›PMID 23345059›Full record

ArticleJournal of the American Society for Mass Spectrometry2013

High-definition differential ion mobility spectrometry with resolving power up to 500.

Alexandre A Shvartsburg, Tom A Seim, William F Danielson, Randy Norheim, Ronald J Moore, Gordon A Anderson, Richard D Smith

Abstract read
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Ion Mobility Separation of Peptide Isotopomers.Journal of the American Society for Mass Spectrometry · 2016
    Article
  12. Review
  13. Article
  14. Article
  15. Review
  16. Differential ion mobility separations in up to 100% helium using microchips.Journal of the American Society for Mass Spectrometry · 2014
    Article
  17. Article
  18. Article
  19. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Alexandre A ShvartsburgBiological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, USA. alexandre.shvartsburg@pnl.gov
Tom A Seim
William F Danielson
Randy Norheim
Ronald J Moore
Gordon A Anderson
Richard D Smith

Funding

Equipment Supplement Request for a Research Resource for Ultra-sensitive High Throughput ProteomicsP41GM103493 · NIGMS · BATTELLE PACIFIC NORTHWEST LABORATORIES · PI SMITH, RICHARD D · 2012 to 2022
$22.6M
NIGMS NIH HHS 8P41 GM 103493-10NIGMS NIH HHS P41 GM103493
6 · The paper itself

Abstract

As the resolution of analytical methods improves, further progress tends to be increasingly limited by instrumental parameter instabilities that were previously inconsequential. This is now the case with differential ion mobility spectrometry (FAIMS), where fluctuations of the voltages and gas pressure have become critical. A new high-definition generator for FAIMS compensation voltage reported here provides a stable and accurate output than can be scanned with negligible steps. This reduces the spectral drift and peak width, thus improving the resolving power (R) and resolution. The gain for multiply-charged peptides that have narrowest peaks is up to ~40%, and R ~400-500 is achievable using He/N(2) or H(2)/N(2) gas mixtures.

Indexed as

GasesIsomerismMass SpectrometryPeptidesGasesPeptides

Identifiers

PMID23345059
PMCPMC3581339

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.