Evidence map›Paper›PMID 23344373›Full record

ArticleSensors (Basel, Switzerland)2012

Flow cell design for effective biosensing.

Douglas J Pike, Nikil Kapur, Paul A Millner, Douglas I Stewart

Abstract readComparative Study
In one paragraph

Article in Sensors (Basel, Switzerland), 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Douglas J PikePathogen Control Engineering (PaCE) Institute, School of Civil Engineering, University of Leeds, Leeds, West Yorkshire, UK. ee09djp@leeds.ac.uk
Nikil Kapur
Paul A Millner
Douglas I Stewart

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The efficiency of three different biosensor flow cells is reported. All three flow cells featured a central channel that expands in the vicinity of the sensing element to provide the same diameter active region, but the rate of channel expansion and contraction varied between the designs. For each cell the rate at which the analyte concentration in the sensor chamber responds to a change in the influent analyte concentration was determined numerically using a finite element model and experimentally using a flow-fluorescence technique. Reduced flow cell efficiency with increasing flow rates was observed for all three designs and was related to the increased importance of diffusion relative to advection, with efficiency being limited by the development of regions of recirculating flow (eddies). However, the onset of eddy development occurred at higher flow rates for the design with the most gradual channel expansion, producing a considerably more efficient flow cell across the range of flow rates considered in this study. It is recommended that biosensor flow cells be designed to minimize the tendency towards, and be operated under conditions that prevent the development of flow recirculation.

Indexed as

Biosensing TechniquesDiffusionElectrodesEquipment DesignFinite Element AnalysisFluorescenceMicrofluidic Analytical TechniquesModels, TheoreticalPolymethyl MethacrylatePolytetrafluoroethylenePolymethyl MethacrylatePolytetrafluoroethylene

Identifiers

PMID23344373
PMCPMC3574664

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.