Evidence map›Paper›PMID 23344137›Full record

ArticleEuropean journal of nuclear medicine and molecular imaging2013

Performance evaluation of small-animal multipinhole μSPECT scanners for mouse imaging.

Steven Deleye, Roel Van Holen, Jeroen Verhaeghe, Stefaan Vandenberghe, Sigrid Stroobants, Steven Staelens

Abstract readEvaluation Study
PubMed Publisher
In one paragraph

Article in European journal of nuclear medicine and molecular imaging, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 36 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
36citing papers in PubMed, 1 pooled it
7.7field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

36 citing papers in PubMed, 1 synthesis or guideline pooled it, 77 citations in OpenAlex.

  1. Preclinical techniques to investigate exercise training in vascular pathophysiology.American journal of physiology. Heart and circulatory physiology · 2021
    Pooled it
  2. Pre-clinical SPECT and SPECT-CT in Oncology.Recent results in cancer research. Fortschritte der Krebsforschung. Progres dans les recherches sur le cancer · 2026
    Review
  3. Article
  4. Individual and Simultaneous Imaging ofIEEE transactions on radiation and plasma medical sciences · 2025
    Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Molecular therapy oncolytics · 2021
    Review
  13. Article
  14. Article
  15. Article
  16. Review
  17. How Non-invasiveFrontiers in physiology · 2020
    Review
  18. Review
  19. Review
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Steven DeleyeMolecular Imaging Center Antwerp, Antwerp University, Universiteitsplein 1, 2610 Antwerp, Belgium. steven.deleye@ua.ac.be
Roel Van Holen
Jeroen Verhaeghe
Stefaan Vandenberghe
Sigrid Stroobants
Steven Staelens
University of Antwerp · BEiMinds · BEAntwerp University Hospital · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeWe compared the performance of three commercial small-animal μSPECT scanners equipped with multipinhole general purpose (GP) and multipinhole high-resolution (HR) collimators designed for imaging mice.

methodsSpatial resolution, image uniformity, point source sensitivity and contrast recovery were determined for the U-SPECT-II (MILabs), the NanoSPECT-NSO (BioScan) and the X-SPECT (GE) scanners. The pinhole diameters of the HR collimator were 0.35 mm, 0.6 mm and 0.5 mm for these three systems respectively. A pinhole diameter of 1 mm was used for the GP collimator. To cover a broad field of imaging applications three isotopes were used with various photon energies: (99m)Tc (140 keV), (111)In (171 and 245 keV) and (125)I (27 keV). Spatial resolution and reconstructed image uniformity were evaluated in both HR and a GP mode with hot rod phantoms, line sources and a uniform phantom. Point source sensitivity and contrast recovery measures were additionally obtained in the GP mode with a novel contrast recovery phantom developed in-house containing hot and cold submillimetre capillaries on a warm background.

resultsIn hot rod phantom images, capillaries as small as 0.4 mm with the U-SPECT-II, 0.75 mm with the X-SPECT and 0.6 mm with the NanoSPECT-NSO could be resolved with the HR collimators for (99m)Tc. The NanoSPECT-NSO achieved this resolution in a smaller field-of-view (FOV) and line source measurements showed that this device had a lower axial than transaxial resolution. For all systems, the degradation in image resolution was only minor when acquiring the more challenging isotopes (111)In and (125)I. The point source sensitivity with (99m)Tc and GP collimators was 3,984 cps/MBq for the U-SPECT-II, 620 cps/MBq for the X-SPECT and 751 cps/MBq for the NanoSPECT-NSO. The effects of volume sensitivity over a larger object were evaluated by measuring the contrast recovery phantom in a realistic FOV and acquisition time. For 1.5-mm rods at a noise level of 8 %, the contrast recovery coefficient (CRC) was 42 %, 37 % and 34 % for the U-SPECT-II, X-SPECT and NanoSPECT-NSO, respectively. At maximal noise levels of 10 %, a CRCcold of 70 %, 52 % and 42 % were obtained for the U-SPECT-II, X-SPECT and NanoSPECT-NSO, respectively. When acquiring (99m)Tc with the GP collimators, the integral/differential uniformity values were 30 %/14 % for the U-SPECT-II, 50 %/30 % for the X-SPECT and 38 %/25 % for the NanoSPECT-NSO. When using the HR collimators, these uniformity values remained similar for U-SPECT-II and X-SPECT, but not for the NanoSPECT-NSO for which the uniformity deteriorated with larger volumes.

conclusionWe compared three μSPECT systems by acquiring and analysing mouse-sized phantoms including a contrast recovery phantom built in-house offering the ability to measure the hot contrast on a warm background in the submillimetre resolution range. We believe our evaluation addressed the differences in imaging potential for each system to realistically image tracer distributions in mouse-sized objects.

Indexed as

AnimalsEquipment DesignMiceRadioisotopesSignal-To-Noise RatioTomography, Emission-Computed, Single-PhotonRadioisotopes

Identifiers

PMID23344137
OpenAlexW1993392901

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.