Evidence map›Paper›PMID 23334190›Full record

ArticleThe international journal of cardiovascular imaging2013

Novel single-source high-pitch protocol for CT angiography of the aorta: comparison to high-pitch dual-source protocol in the context of TAVI planning.

Bernhard Bischoff, Felix G Meinel, Maximilian Reiser, Hans-Christoph Becker

Abstract readComparative StudyEvaluation Study
PubMed Publisher
In one paragraph

Article in The international journal of cardiovascular imaging, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.6field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 16 citations in OpenAlex.

  1. Trial
  2. Review
  3. TAVI imaging: over the echocardiography.La Radiologia medica · 2020
    Review
  4. Article
  5. Cardiovascular imaging 2013 in the International Journal of Cardiovascular Imaging.The international journal of cardiovascular imaging · 2014
    Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Bernhard BischoffInstitute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, Marchioninistrasse 15, 81377 Munich, Germany. Bernhard.Bischoff@med.uni-muenchen.de
Felix G Meinel
Maximilian Reiser
Hans-Christoph Becker
German Centre for Cardiovascular Research · DELudwig-Maximilians-Universität München · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose Computed tomography (CT) is increasingly being used for planning purposes prior to trans-arterial valve implantation (TAVI). High-pitch protocols using a 2nd generation dual-source CT (DSCT) allow for a comprehensive assessment of the aortic valve anulus, its distance to the coronary artery ostia, the aortic bulbus and the iliofemoral arteries with very low radiation exposure and low amount of contrast agent. The aim of this study was to evaluate the image quality of a comparable high-pitch scan mode in a modern single-source CT (SSCT) system. Methods 40 patients with severe symptomatic aortic valve stenosis have been examined for planning purposes prior to TAVI. The first 20 consecutive patients were examined with a 2nd generation DSCT system using a high-pitch scan mode (pitch value 3.4) and 60 ml of contrast agent. The second group of 20 consecutive patients were examined with a 128-slice SSCT system, using a high-pitch scan mode (pitch value of 1.7) and 60 ml of contrast agent. Image quality of the aortic valve, the ascending aorta, the coronary artery ostia, the iliofemoral arteries and overall image quality were graded in a blinded fashion using a 4-point-grading-scale. Furthermore, signal intensity and image noise were derived in the ascending aorta and in the ilio-femoral arteries. Results There was a minor but significant difference in the overall image quality score with lower image quality in SSCT (3.5 ± 0.6) when compared to DSCT (3.85 ± 0.4; p = 0.037). The mean image quality score was significantly higher in patients examined in DSCT when compared to SSCT regarding the evaluability of the coronary ostia (4.0 vs. 3.5; p < 0.01) and the image quality of the ascending aorta (4.0 vs. 3.5; p < 0.01). There was no significant difference in evaluation of the aortic valve and its anulus (3.85 for DSCT and 3.65 for SSCT; p = 0.149) and image quality of the iliofemoral arteries (3.65 for DSCT and 3.85 for SSCT; p = 0.140). Signal intensity and image noise did not differ significantly between both groups. Conclusions This study presents a novel high-pitch protocol for modern SSCT scanners, which allows CT angiography for TAVI planning with a similar radiation dose and contrast agent exposition and only small compromises in image quality compared to a high-pitch protocol on a DSCT scanner.

Indexed as

Cardiac CatheterizationMultidetector Computed TomographyAgedAged, 80 and overAortic ValveAortic Valve StenosisAortographyContrast MediaFemaleHeart Valve Prosthesis ImplantationHumansMalePredictive Value of TestsRadiographic Image Interpretation, Computer-AssistedRetrospective StudiesSeverity of Illness IndexContrast Media

Identifiers

PMID23334190
OpenAlexW2126073007

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.