Evidence map›Paper›PMID 23329739›Full record

ArticleJournal of chromatographic science2014

Performance comparisons of nano-LC systems, electrospray sources and LC-MS-MS platforms.

Qian Liu, Jennifer S Cobb, Joshua L Johnson, Qi Wang, Jeffrey N Agar

Abstract readComparative Study
In one paragraph

Article in Journal of chromatographic science, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Ultrasensitive quantification of trace amines based onJournal of pharmaceutical analysis · 2023
    Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Qian Liu1Department of Chemistry.
Jennifer S Cobb
Joshua L Johnson
Qi Wang
Jeffrey N Agar

Funding

Macromolecular Structure MechanismT32GM007596 · NIGMS · BRANDEIS UNIVERSITY · PI OPRIAN, DANIEL D · 1985 to 2019
$4.5M
Structural Consequences of ALS-related Modifications of SOD1R01NS065263 · NINDS · NORTHEASTERN UNIVERSITY · PI AGAR, JEFFREY NEIL · 2009 to 2013
$1.7M
NIGMS NIH HHS T32 GM007596NINDS NIH HHS R01 NS065263NINDS NIH HHS R01NS065263
6 · The paper itself

Abstract

Selecting a suitable nano-liquid chromatography system (LC), ionization source and mass spectrometer for LC-tandem mass spectrometry (MS-MS) studies is complicated by numerous competing technologies. This study compares four popular nano-LC systems, four ionization sources and three MS facilities that use completely different LC-MS-MS systems. Statistically significant differences in LC performance were identified with similarly performing Proxeon, Waters and Eksigent nanoLC-Ultra systems [retention time routinely at 0.7-0.9% relative standard deviation (RSD)], and all outperformed the Eksigent nanoLC-2D (RSD ∼2%). In addition, compatibility issues were identified between the Bruker HCT ion trap mass spectrometer and both the Eksigent nanoLC-2D and the Bruker nanoelectrospray source. The electrospray source itself had an unexpected and striking effect on chromatographic reproducibility on the Bruker HCT ion trap. The New Objective nanospray source significantly outperformed the Bruker nanospray source in retention time RSD (1% RSD versus 14% RSD, respectively); and the Bruker nebulized nanospray source outperformed both of these traditional, non-nebulized sources (0.5% RSD in retention time). Finally, to provide useful benchmarks for overall proteomics sensitivity, different LC-MS-MS platforms were compared by analyzing a range of concentrations of tryptic digests of bovine serum albumin at three MS facilities. The results indicate that similar sensitivity can be realized with a Bruker HCT-Ultra ion trap, a Thermo LTQ-Velos Linear ion trap and a Thermo LTQ-Orbitrap XL-ETD.

Indexed as

Chromatography, LiquidNanotechnologyProteomicsReproducibility of ResultsSensitivity and SpecificitySpectrometry, Mass, Electrospray IonizationTandem Mass Spectrometry

Identifiers

PMID23329739
PMCPMC3886563

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.