Evidence map›Paper›PMID 23326181›Full record

ArticleIEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division2012

Development and Evaluation of an Actuated MRI-Compatible Robotic System for MRI-Guided Prostate Intervention.

Axel Krieger, Sang-Eun Song, Nathan B Cho, Iulian Iordachita, Peter Guion, Gabor Fichtinger, Louis L Whitcomb

Open access · greenAbstract read
In one paragraph

Article in IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 47 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
47citing papers in PubMed, 1 pooled it
4.5field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

47 citing papers in PubMed, 1 synthesis or guideline pooled it, 121 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. A Pneumatically Actuated Robotic Assistant for MRI-Guided Stereotactic Neurosurgery.IEEE transactions on medical robotics and bionics · 2026
    Article
  4. Review
  5. Review
  6. Article
  7. Article
  8. Article
  9. Towards Design and Development of an MRI Conditional Robot to Enable Curvilinear Transperineal Prostate Biopsy.The international journal of medical robotics + computer assisted surgery : MRCAS · 2024
    Article
  10. Review
  11. Open Source MR-Safe Pneumatic Radial Inflow Motor and Encoder (PRIME): Design and Manufacturing Guidelines.... International Symposium on Medical Robotics. International Symposium on Medical Robotics · 2023
    Article
  12. MR conditional prostate intervention systems and actuations review.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2023
    Review
  13. State of the Art and Future Opportunities in MRI-Guided Robot-Assisted Surgery and Interventions.Proceedings of the IEEE. Institute of Electrical and Electronics Engineers · 2022
    Article
  14. MRI-guided lumbar spinal injections with body-mounted robotic system: cadaver studies.Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy · 2022
    Article
  15. Article
  16. Article
  17. Simple methods to test the accuracy of MRgFUS robotic systems.The international journal of medical robotics + computer assisted surgery : MRCAS · 2021
    Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Axel KriegerDepartment of Mechanical Engineering and the Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, Maryland, USA, and is presently with Sentinelle Medical Inc., Toronto, Canada.
Sang-Eun Song
Nathan B Cho
Iulian Iordachita
Peter Guion
Gabor Fichtinger
Louis L Whitcomb
Johns Hopkins University · USNational Institutes of Health · USQueen's University · CA

Funding

Transrectal Prostate Therapy Robot in Closed MRI ScannerR01EB002963 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI WHITCOMB, LOUIS LITCHFIELD · 2003 to 2007
$2.0M
NIBIB NIH HHS R01 EB002963
6 · The paper itself

Abstract

This paper reports the design, development, and magnetic resonance imaging (MRI) compatibility evaluation of an actuated transrectal prostate robot for MRI-guided needle intervention in the prostate. The robot performs actuated needle MRI-guidance with the goals of providing (i) MRI compatibility, (ii) MRI-guided needle placement with accuracy sufficient for targeting clinically significant prostate cancer foci, (iii) reducing interventional procedure times (thus increasing patient comfort and reducing opportunity for needle targeting error due to patient motion), (iv) enabling real-time MRI monitoring of interventional procedures, and (v) reducing the opportunities for error that arise in manually actuated needle placement. The design of the robot, employing piezo-ceramic-motor actuated needle guide positioning and manual needle insertion, is reported. Results of a MRI compatibility study show no reduction of MRI signal-to-noise-ratio (SNR) with the motors disabled. Enabling the motors reduces the SNR by 80% without RF shielding, but SNR is only reduced by 40% to 60% with RF shielding. The addition of radio-frequency shielding is shown to significantly reduce image SNR degradation caused by the presence of the robotic device. An accuracy study of MRI-guided biopsy needle placements in a prostate phantom is reported. The study shows an average in-plane targeting error of 2.4 mm with a maximum error of 3.7 mm. These data indicate the system's needle targeting accuracy is similar to that obtained with a previously reported manually actuated system, and is sufficient to reliably sample clinically significant prostate cancer foci under MRI-guidance.

Identifiers

PMID23326181
PMCPMC3544166
OpenAlexW2017756316

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.