Evidence map›Paper›PMID 23321457›Full record

ArticleJournal of nuclear medicine : official publication, Society of Nuclear Medicine2013

Myocardial perfusion imaging with a solid-state camera: simulation of a very low dose imaging protocol.

Ryo Nakazato, Daniel S Berman, Sean W Hayes, Mathews Fish, Richard Padgett, Yuan Xu, Mark Lemley, Rafael Baavour, Nathaniel Roth, Piotr J Slomka

Open access · bronzeAbstract read
In one paragraph

Article in Journal of nuclear medicine : official publication, Society of Nuclear Medicine, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 59 papers.

0numbers the graph read from it
0cells of the map it votes in
59citing papers in PubMed
15.1field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

59 citing papers in PubMed, 108 citations in OpenAlex.

  1. Dose reduction in half-time myocardial perfusion SPECT-CT with multifocal collimation.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2016
    Trial
  2. Development and validation of a patient-tailored dose regime in myocardial perfusion imaging using conventional SPECT.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2016
    Trial
  3. Development and validation of a patient-tailored dose regime in myocardial perfusion imaging using CZT-SPECT.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2014
    Trial
  4. Article
  5. Comparison of 2D-QCA, 3D-QCA and coronary angiography derived FFR in predicting myocardial ischemia assessed by CZT-SPECT MPI.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2023
    Article
  6. Deep learning-based denoising in projection-domain and reconstruction-domain for low-dose myocardial perfusion SPECT.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2023
    Article
  7. Personalization ofEJNMMI physics · 2023
    Article
  8. Article
  9. Review
  10. Do we need dedicated cardiac SPECT systems?Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021
    Article
  11. Review
  12. Article
  13. Effect of reduced photon count levels and choice of normal data on semi-automated image assessment in cardiac SPECT.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2020
    Article
  14. Effect of reduced photon count levels and choice of normal data on semi-automated image assessment in cardiac SPECT: Doing more with fewer counts.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2020
    Article
  15. Quantitative Clinical Nuclear Cardiology, Part 1: Established Applications.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2020
    Review
  16. Quantitative Clinical Nuclear Cardiology, Part 1: Established Applications.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2019
    Review
  17. Article
  18. Impact of non-specific normal databases on perfusion quantification of low-dose myocardial SPECT studies.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2019
    Article
  19. Minimal rest activity for SPECT myocardial perfusion imaging in a one-day stress-first protocol.European journal of nuclear medicine and molecular imaging · 2019
    Article
  20. Automatic evaluation of myocardial perfusion on SPECT: Need for "Normality".Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2019
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 1 country.

Ryo NakazatoDepartment of Imaging and Medicine, and Cedars-Sinai Heart Institute, Cedars-Sinai Medical Center, Los Angeles, California 90048, USA.
Daniel S Berman
Sean W Hayes
Mathews Fish
Richard Padgett
Yuan Xu
Mark Lemley
Rafael Baavour
Nathaniel Roth
Piotr J Slomka
Cedars-Sinai Medical Center · USSacred Heart Medical Center · USProvidence Sacred Heart Medical Center · US

Funding

Quantitative Prediction of Disease and Outcomes from Next Generation SPECT and CTR01HL089765 · NHLBI · CEDARS-SINAI MEDICAL CENTER · PI SLOMKA, PIOTR J · 2007 to 2021
$6.1M
NHLBI NIH HHS R01 HL089765NHLBI NIH HHS R01-HL089765
6 · The paper itself

Abstract

unlabelledHigh-sensitivity dedicated cardiac camera systems provide an opportunity to lower the injected doses for SPECT myocardial perfusion imaging (MPI), but the exact limits for lowering doses have not been determined. List-mode data acquisition allows for reconstruction of various fractions of acquired counts, enabling a simulation of gradually lower administered dose. We aimed to determine the feasibility of very low dose MPI by exploring the minimal count level in the myocardium required for accurate MPI.

methodsSeventy-nine patients were studied (mean body mass index, 30.0 ± 6.6; range, 20.2-54.0 kg/m(2)) who underwent 1-d standard-dose (99m)Tc-sestamibi exercise or adenosine rest-stress MPI for clinical indications using a cadmium-zinc-telluride dedicated cardiac camera. The imaging time was 14 min, with averaged 803 ± 200 MBq (21.7 ± 5.4 mCi) of (99m)Tc injected at stress. To simulate clinical scans with a lower dose at that imaging time we reframed the list-mode raw data. Accordingly, 6 stress-equivalent datasets were reconstructed containing various count fractions of the original scan. Automated quantitative perfusion and gated SPECT software was used to quantify total perfusion deficit (TPD) and ejection fraction for all 553 datasets (7 × 79). The minimal acceptable left ventricular region counts were determined on the basis of a previous report with repeatability of same-day, same-injection Anger camera studies. Pearson correlation coefficients and the SD of differences in TPD for all scans were calculated.

resultsThe correlations of quantitative perfusion and function analysis were excellent for both global and regional analysis between original scans and all simulated low-count scans (all r ≥ 0.95, P < 0.0001). The minimal acceptable counts were determined to be 1.0 million for the left ventricular region. At this count level, the SD of differences was 1.7% for TPD and 4.2% for ejection fraction. This count level would correspond to a 92.5-MBq (2.5-mCi) injected dose for the 14-min acquisition or 125.8-MBq (3.4-mCi) injected dose for the 10-min acquisition.

conclusion1.0 million counts appear to be sufficient to produce myocardial images that agree well with 8.0-million-count images on quantitative perfusion and function parameters. With a dedicated cardiac camera, these images can be obtained over 10 min with an effective radiation dose of less than 1 mSv without significant sacrifice of accuracy.

Indexed as

AgedClinical ProtocolsComputer SimulationFemaleGamma CamerasHumansImage Interpretation, Computer-AssistedMaleMiddle AgedMyocardial Perfusion ImagingRadiation DosageRadiopharmaceuticalsSoftwareStroke VolumeTechnetium Tc 99m SestamibiTomography, Emission-Computed, Single-PhotonRadiopharmaceuticalsTechnetium Tc 99m Sestamibi

Identifiers

PMID23321457
PMCPMC3594528
OpenAlexW2161555101

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.