Evidence map›Paper›PMID 23320033›Full record

ArticleEvidence-based complementary and alternative medicine : eCAM2012

Electrical potential of acupuncture points: use of a noncontact scanning Kelvin probe.

Brian J Gow, Justine L Cheng, Iain D Baikie, Orjan G Martinsen, Min Zhao, Stephanie Smith, Andrew C Ahn

Abstract read
In one paragraph

Article in Evidence-based complementary and alternative medicine : eCAM, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Article
  6. Power Spectrum Features of Acupoint Bioelectricity Signal.Evidence-based complementary and alternative medicine : eCAM · 2021
    Article
  7. Article
  8. Energy Medicine: Current Status and Future Perspectives.Global advances in health and medicine · 2019
    Article
  9. Visualization of the Meridian System Based on Biomedical Information about Acupuncture Treatment.Evidence-based complementary and alternative medicine : eCAM · 2013
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Brian J GowOsher Center for Integrative Medicine, Brigham and Women's Hospital, 900 Commonwealth Avenue, Boston, MA 02215, USA.
Justine L Cheng
Iain D Baikie
Orjan G Martinsen
Min Zhao
Stephanie Smith
Andrew C Ahn

Funding

HARVARD CLINICAL AND TRANSLATIONAL SCIENCE CENTER (UL1)UL1RR025758 · NCRR · HARVARD MEDICAL SCHOOL · PI NADLER, LEE MARSHALL · 2008 to 2011
$91.4M
Core Center for Multimodal Evaulation of Acupuncture MechanismsP30AT005895 · NCCIH · MASSACHUSETTS GENERAL HOSPITAL · PI ROSEN, BRUCE R · 2009 to 2010
$1.2M
Electrical Potential at Acupuncture Points: Using a Novel Biokelvin ProbeR21AT005249 · NCCIH · MASSACHUSETTS GENERAL HOSPITAL · PI AHN, ANDREW C · 2009 to 2011
$592k
NCCIH NIH HHS P30 AT005895NCCIH NIH HHS R21 AT005249NCRR NIH HHS UL1 RR025758
6 · The paper itself

Abstract

Objective. Acupuncture points are reportedly distinguishable by their electrical properties. However, confounders arising from skin-to-electrode contact used in traditional electrodermal methods have contributed to controversies over this claim. The Scanning Kelvin Probe is a state-of-the-art device that measures electrical potential without actually touching the skin and is thus capable of overcoming these confounding effects. In this study, we evaluated the electrical potential profiles of acupoints LI-4 and PC-6 and their adjacent controls. We hypothesize that acupuncture point sites are associated with increased variability in potential compared to adjacent control sites. Methods. Twelve healthy individuals were recruited for this study. Acupuncture points LI-4 and PC-6 and their adjacent controls were assessed. A 2 mm probe tip was placed over the predetermined skin site and adjusted to a tip-to-sample distance of 1.0 mm under tip oscillation settings of 62.4 Hz frequency. A 6 × 6 surface potential scan spanning a 1.0 cm × 1.0 cm area was obtained. Results. At both the PC-6 and LI-4 sites, no significant differences in mean potential were observed compared to their respective controls (Wilcoxon rank-sum test, P = 0.73 and 0.79, resp.). However, the LI-4 site was associated with significant increase in variability compared to its control as denoted by standard deviation and range (P = 0.002 and 0.0005, resp.). At the PC-6 site, no statistical differences in variability were observed. Conclusion. Acupuncture points may be associated with increased variability in electrical potential.

Identifiers

PMID23320033
PMCPMC3541002

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.