ArticleEuropean journal of nuclear medicine and molecular imaging2013
PET/MR imaging of the pelvis in the presence of endoprostheses: reducing image artifacts and increasing accuracy through inpainting.
Article in European journal of nuclear medicine and molecular imaging, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
20 citing papers in PubMed.
- A review of PET attenuation correction methods for PET-MR.EJNMMI physics · 2023Review
- Attenuation correction for PET/MRI to measure tracer activity surrounding total knee arthroplasty.European journal of hybrid imaging · 2022Article
- Clinical utilization of whole-body PET/MRI in childhood sarcoma.Pediatric radiology · 2021Article
- Attenuation correction for human PET/MRI studies.Physics in medicine and biology · 2020Article
- Metal artifact reduction inEuropean journal of hybrid imaging · 2020Article
- Assessment of attenuation correction for myocardial PET imaging using combined PET/MRI.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2019Article
- Review
- Applications of PET-Computed Tomography-Magnetic Resonance in the Management of Benign Musculoskeletal Disorders.PET clinics · 2019Review
- Clinical evaluation of TOF versus non-TOF on PET artifacts in simultaneous PET/MR: a dual centre experience.European journal of nuclear medicine and molecular imaging · 2017Article
- PET/MRI in the Presence of Metal Implants: Completion of the Attenuation Map from PET Emission Data.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2017Article
- MR Imaging-Guided Attenuation Correction of PET Data in PET/MR Imaging.PET clinics · 2016Review
- Dental artifacts in the head and neck region: implications for Dixon-based attenuation correction in PET/MR.EJNMMI physics · 2015Article
- [F-18]2-fluoro-2-deoxyglucose (FDG) positron emission tomography after limb salvage surgery: post-surgical appearance, attenuation correction and local complications.Pediatric radiology · 2015Article
- Automatic correction of dental artifacts in PET/MRI.Journal of medical imaging (Bellingham, Wash.) · 2015Article
- Clinical assessment of MR-guided 3-class and 4-class attenuation correction in PET/MR.Molecular imaging and biology · 2015Article
- Impact of incorrect tissue classification in Dixon-based MR-AC: fat-water tissue inversion.EJNMMI physics · 2014Article
- The effect of metal artefact reduction on CT-based attenuation correction for PET imaging in the vicinity of metallic hip implants: a phantom study.Annals of nuclear medicine · 2014Article
- Does the novel integrated PET/MRI offer the same diagnostic performance as PET/CT for oncological indications?PloS one · 2014Article
- [Value of new MR techniques in MR-PET].Der Radiologe · 2013Article
- Image quality assessment of automatic three-segment MR attenuation correction vs. CT attenuation correction.American journal of nuclear medicine and molecular imaging · 2013Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeIn combined whole-body PET/MR, attenuation correction (AC) is performed indirectly using the available MR image information and subsequent segmentation. Implant-induced susceptibility artifacts and subsequent signal voids may challenge MR-based AC (MR-AC). We evaluated the accuracy of MR-AC in PET/MR in patients with metallic endoprostheses, and propose a clinically feasible correction method.
methodsWe selected patients with uni- or bilateral endoprostheses from 61 consecutive referrals for whole-body PET/MR imaging (mMR; Siemens Healthcare). Simultaneous whole-body PET/MR imaging was performed at 120 min after injection of about 300 MBq [(18)F]FDG. MR-AC was performed using (1) original MR images and subsequent Dixon water-fat segmentation, (2) as method 1 with implant-induced signal voids filled with soft tissue, (3) as method 2 with superimposed coregistered endoprostheses from the CT scan, and (4) as method 1 with implant-induced signal voids filled with metal. Following MR-AC (methods 1-4) PET emission images were reconstructed on 344 × 344 matrices using attenuation-weighted OSEM (three iterations, 21 subsets, 4 mm gaussian). Maximum body-weight normalized standardized uptake values (SUVmax) were obtained for both hips. Mean SUV (SUVmean) in homogeneous reference regions in the gluteal muscle and bladder following MR-AC (methods 1-4) are also reported.
resultsIn total, four patients presented with endoprostheses, unilateral in two and bilateral in two. The fraction of voxels in MR images affected by the implant was at least twice that of the voxels representing the actual implants. MR-AC using methods 2 and 3 recovered the FDG distribution pattern compared to uncorrected PET images and method 1, while method 4 resulted in severe overestimation of FDG uptake (>460 % SUVmax). When compared to method 1, relative changes in SUVmean in the reference regions from method 2 and 3 were generally small albeit not correlated with the fraction of the attenuation image affected by implant-induced artifacts.
conclusionsEndoprostheses cause PET/MR artifacts that exceed the volume occupied by the implants, and bias PET quantification. Artifacts and bias can be corrected by semiautomated inpainting with soft tissue with a single composition prior to MR-AC, thus restoring quantitative activity distribution.
Indexed as
Identifiers
23296642What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.