ArticleJournal of diabetes science and technology2012
Continuous monitoring of glucose in subcutaneous tissue using microfabricated differential affinity sensors.
Article in Journal of diabetes science and technology, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 6 citations in OpenAlex.
- Emerging Biomarkers and Nanobiosensing Strategies in Diabetes.Biosensors · 2025Review
- A differential dielectric affinity glucose sensor.Lab on a chip · 2014Article
- A MEMS differential viscometric sensor for affinity glucose detection in continuous glucose monitoring.Journal of micromechanics and microengineering : structures, devices, and systems · 2013Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 3 institutions in 1 country.
Funding
Abstract
objectiveWe describe miniaturized differential glucose sensors based on affinity binding between glucose and a synthetic polymer. The sensors possess excellent resistance to environmental disturbances and can potentially allow wireless measurements of glucose concentrations within interstitial fluid in subcutaneous tissue for long-term, stable continuous glucose monitoring (CGM).
methodsThe sensors are constructed using microelectromechanical systems (MEMS) technology and exploit poly(N-hydroxy-ethyl acrylamide-ran-3-acrylamidophenylboronic acid) (PHEAA-ran-PAAPBA), a glucose-binding polymer with excellent specificity, reversibility, and stability. Two sensing approaches have been investigated, which respectively, use a pair of magnetically actuated diaphragms and perforated electrodes to differentially measure the glucose-binding-induced changes in the viscosity and permittivity of the PHEAA-ran-PAAPBA solution with respect to a reference, glucose-unresponsive polymer solution.
resultsIn vivo characterization of the MEMS affinity sensors were performed by controlling blood glucose concentrations of laboratory mice by exogenous glucose and insulin administration. The sensors experienced an 8-30 min initialization period after implantation and then closely tracked commercial capillary glucose meter readings with time lags ranging from 0-15 min during rapid glucose concentration changes. Clarke error grid plots obtained from sensor calibration suggest that, for the viscometric and dielectric sensors, respectively, approximately 95% (in the hyperglycemic range) and 84% (ranging from hypoglycemic to hyperglycemic glucose concentrations) of measurement points were clinically accurate, while 5% and 16% of the points were clinically acceptable.
conclusionsThe miniaturized MEMS sensors explore differential measurements of affinity glucose recognition. In vivo testing demonstrated excellent accuracy and stability, suggesting that the devices hold the potential to enable long-term and reliable CGM in clinical applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.