ArticleJournal of diabetes science and technology2012
Biofouling of polymer hydrogel materials and its effect on diffusion and enzyme-based luminescent glucose sensor functional characteristics.
Article in Journal of diabetes science and technology, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 28 citations in OpenAlex.
- Cross-Linkable Polymer-Based Multi-layers for Protecting Electrochemical Glucose Biosensors against Uric Acid, Ascorbic Acid, and Biofouling Interferences.ACS sensors · 2023Article
- NIR Luminescent Oxygen-Sensing Nanoparticles for Continuous Glucose and Lactate Monitoring.Biosensors · 2023Article
- Inorganic-Organic Interpenetrating Network Hydrogels as Tissue-Integrating Luminescent Implants: Physicochemical Characterization and Preclinical Evaluation.Macromolecular bioscience · 2022Article
- Near-Infrared Optical Nanosensors for Continuous Detection of Glucose.Journal of diabetes science and technology · 2020Article
- An Optical Urate Biosensor Based on Urate Oxidase and Long-Lifetime Metalloporphyrins.Sensors (Basel, Switzerland) · 2020Article
- In Vivo Biosensing: Progress and Perspectives.ACS sensors · 2017Article
- Characterization of Lactate Sensors Based on Lactate Oxidase and Palladium Benzoporphyrin Immobilized in Hydrogels.Biosensors · 2015Article
- Preclinical Evaluation of Poly(HEMA-co-acrylamide) Hydrogels Encapsulating Glucose Oxidase and Palladium Benzoporphyrin as Fully Implantable Glucose Sensors.Journal of diabetes science and technology · 2015Article
- Enzymatic Glucose Sensor Compensation for Variations in Ambient Oxygen Concentration.Proceedings of SPIE--the International Society for Optical Engineering · 2015Article
- Cell based metabolic barriers to glucose diffusion: macrophages and continuous glucose monitoring.Biomaterials · 2014Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
Abstract
backgroundContinuous glucose monitoring is crucial to developing a successful artificial pancreas. However, biofouling and host response make in vivo sensor performance difficult to predict. We investigated changes in glucose diffusivity and sensor response of optical enzymatic glucose sensors due to biological exposure.
methodThree hydrogel materials, poly(2-hydroxyethyl methacrylate) (pHEMA), poly(acrylamide) (pAM), and poly(2-hydroxyethyl methacrylate)-co-poly(acrylamide) (p(HEMA-co-AM)), were tested for glucose diffusivity before and after exposure to serum or implantation in rats for 1 month. Luminescent sensors based on these materials were measured to compare the response to glucose before and after serum exposure.
resultsGlucose diffusivity through the pHEMA [(8.1 ± 0.38) × 10(-8) cm(2)/s] slabs was much lower than diffusivity through pAM [(2.7 ± 0.15) × 10(-6) cm(2)/s] and p(HEMA-co-AM) [(2.5 ± 0.08) × 10(-6)]. As expected from these differences, sensor response was highly dependent on material type. The pHEMA sensors had a maximum sensitivity of 2.5%/(mg/dl) and an analytical range of 4.2-356 mg/dl, while the p(HEMA-co-AM) sensors had a higher sensitivity [14.9%/(mg/dl)] and a narrower analytical range (17.6-70.5 mg/dl). After serum exposure, the pHEMA sensors were unaffected, whereas the p(HEMA-co-AM) sensors exhibited significantly decreased sensitivity and increased analytical range.
conclusionsDecreases in glucose diffusivity in the polymers resulting from in vitro serum exposure and residence in vivo were shown to be similar, suggesting that serum incubation was a reasonable approximation of in vivo fouling. While biofouling is expected to affect the response of flux-based sensors, we have shown that this depended on the type of sensor and matrix used. Therefore, proper design and materials selection may minimize response alterations occurring upon implantation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials