Evidence map›Paper›PMID 23291269›Full record

ReviewMicroscopy (Oxford, England)2013

Problems in obtaining perfect images by single-particle electron cryomicroscopy of biological structures in amorphous ice.

Richard Henderson, Greg McMullan

Open access · hybridAbstract readReview
In one paragraph

Review in Microscopy (Oxford, England), 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 28 papers.

0numbers the graph read from it
0cells of the map it votes in
28citing papers in PubMed
8.2field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

28 citing papers in PubMed, 47 citations in OpenAlex.

  1. Article
  2. Article
  3. Multi-species cryoEM calibration and workflow verification standard.Acta crystallographica. Section F, Structural biology communications · 2024
    Article
  4. Multi-species cryoEM calibration and workflow verification standard.bioRxiv : the preprint server for biology · 2024
    Article
  5. Structure determination by cryoEM at 100 keV.Proceedings of the National Academy of Sciences of the United States of America · 2023
    Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Article
  16. Review
  17. Processing apoferritin with the Appion pipeline.Journal of structural biology · 2018
    Article
  18. Article
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Richard HendersonMRC Laboratory of Molecular Biology, Hills Road, Cambridge, UK. rh15@mrc-lmb.cam.ac.uk
Greg McMullan
MRC Laboratory of Molecular Biology · GB

Funding

Medical Research Council MC_U105184322Medical Research Council U105184322
6 · The paper itself

Abstract

Theoretical considerations together with simulations of single-particle electron cryomicroscopy images of biological assemblies in ice demonstrate that atomic structures should be obtainable from images of a few thousand asymmetric units, provided the molecular weight of the whole assembly being studied is greater than the minimum needed for accurate position and orientation determination. However, with present methods of specimen preparation and current microscope and detector technologies, many more particles are needed, and the alignment of smaller assemblies is difficult or impossible. Only larger structures, with enough signal to allow good orientation determination and with enough images to allow averaging of many hundreds of thousands or even millions of asymmetric units, have successfully produced high-resolution maps. In this review, we compare the contrast of experimental electron cryomicroscopy images of two smaller molecular assemblies, namely apoferritin and beta-galactosidase, with that expected from perfect simulated images calculated from their known X-ray structures. We show that the contrast and signal-to-noise ratio of experimental images still require significant improvement before it will be possible to realize the full potential of single-particle electron cryomicroscopy. In particular, although reasonably good orientations can be obtained for beta-galactosidase, we have been unable to obtain reliable orientation determination from experimental images of apoferritin. Simulations suggest that at least 2-fold improvement of the contrast in experimental images at ~10 Å resolution is needed and should be possible.

Indexed as

IceApoferritinsbeta-GalactosidaseCryoelectron MicroscopyImage Processing, Computer-AssistedMolecular StructureSignal-To-Noise RatioX-RaysApoferritinsbeta-GalactosidaseIce

Identifiers

PMID23291269
PMCPMC3767125
OpenAlexW2158775527

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.