Evidence map›Paper›PMID 23287923›Full record

ArticleIEEE transactions on ultrasonics, ferroelectrics, and frequency control2013

A flexible annular-array imaging platform for micro-ultrasound.

Weibao Qiu, Yanyan Yu, Hamid Reza Chabok, Cheng Liu, Fu Keung Tsang, Qifa Zhou, K Kirk Shung, Hairong Zheng, Lei Sun

Abstract read
In one paragraph

Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Secured computed tomography scanner using a random bit.Technology and health care : official journal of the European Society for Engineering and Medicine · 2023
    Article
  4. Development of a low-cost six-axis alignment instrument for flexible 2D and 3D ultrasonic probes.Technology and health care : official journal of the European Society for Engineering and Medicine · 2021
    Article
  5. Article
  6. Article
  7. Article
  8. A Novel Fisheye-Lens-Based Photoacoustic System.Sensors (Basel, Switzerland) · 2016
    Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Weibao QiuInterdisciplinary Division of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR, China.
Yanyan Yu
Hamid Reza Chabok
Cheng Liu
Fu Keung Tsang
Qifa Zhou
K Kirk Shung
Hairong Zheng
Lei Sun

Funding

A Resource on Medical Ultrasonic Transducer TechnologyP41EB002182 · NIBIB · UNIVERSITY OF SOUTHERN CALIFORNIA · PI SHUNG, K KIRK · 2003 to 2016
$13.3M
Ultrasonic System for Cardiac Imaging in Small AnimalsR01HL079976 · NHLBI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI SHUNG, K KIRK · 2005 to 2011
$2.0M
NHLBI NIH HHS R01 HL079976NIBIB NIH HHS P41 EB002182NIBIB NIH HHS P41-EB2182
6 · The paper itself

Abstract

Micro-ultrasound is an invaluable imaging tool for many clinical and preclinical applications requiring high resolution (approximately several tens of micrometers). Imaging systems for micro-ultrasound, including single-element imaging systems and linear-array imaging systems, have been developed extensively in recent years. Single-element systems are cheaper, but linear-array systems give much better image quality at a higher expense. Annular-array-based systems provide a third alternative, striking a balance between image quality and expense. This paper presents the development of a novel programmable and real-time annular-array imaging platform for micro-ultrasound. It supports multi-channel dynamic beamforming techniques for large-depth-of-field imaging. The major image processing algorithms were achieved by a novel field-programmable gate array technology for high speed and flexibility. Real-time imaging was achieved by fast processing algorithms and high-speed data transfer interface. The platform utilizes a printed circuit board scheme incorporating state-of-the-art electronics for compactness and cost effectiveness. Extensive tests including hardware, algorithms, wire phantom, and tissue mimicking phantom measurements were conducted to demonstrate good performance of the platform. The calculated contrast-to-noise ratio (CNR) of the tissue phantom measurements were higher than 1.2 in the range of 3.8 to 8.7 mm imaging depth. The platform supported more than 25 images per second for real-time image acquisition. The depth-of-field had about 2.5-fold improvement compared to single-element transducer imaging.

Indexed as

AlgorithmsEquipment DesignImage Processing, Computer-AssistedMicrotechnologyModels, BiologicalPhantoms, ImagingTransducersUltrasonography

Identifiers

PMID23287923
PMCPMC3738186

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.