Evidence map›Paper›PMID 23267185›Full record

ReviewPhilosophical transactions of the Royal Society of London. Series B, Biological sciences2013

Development of new photon-counting detectors for single-molecule fluorescence microscopy.

X Michalet, R A Colyer, G Scalia, A Ingargiola, R Lin, J E Millaud, S Weiss, Oswald H W Siegmund, Anton S Tremsin, John V Vallerga and 12 more

Open access · bronzeAbstract readReview
In one paragraph

Review in Philosophical transactions of the Royal Society of London. Series B, Biological sciences, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 31 papers.

0numbers the graph read from it
0cells of the map it votes in
31citing papers in PubMed
12.6field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

31 citing papers in PubMed, 117 citations in OpenAlex.

  1. Article
  2. Choosing the Probe for Single-Molecule Fluorescence Microscopy.International journal of molecular sciences · 2022
    Review
  3. Article
  4. Fast Gating for Raman Spectroscopy.Sensors (Basel, Switzerland) · 2021
    Review
  5. Article
  6. Wide-field time-correlated single photon counting-based fluorescence lifetime imaging microscopy.Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment · 2019
    Review
  7. Article
  8. Review
  9. Optical crosstalk in SPAD arrays for high-throughput single-molecule fluorescence spectroscopy.Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment · 2018
    Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Development and characterization of an 8×8 SPAD-array module for gigacount per second applications.Proceedings of SPIE--the International Society for Optical Engineering · 2017
    Article
  15. Article
  16. Article
  17. Silicon technologies for arrays of Single Photon Avalanche Diodes.Proceedings of SPIE--the International Society for Optical Engineering · 2016
    Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

22 authors at 3 institutions in 2 countries.

X MichaletDepartment of Chemistry and Biochemistry, UCLA, Los Angeles, CA 90095-1547, USA. michalet@chem.ucla.edu
R A Colyer
G Scalia
A Ingargiola
R Lin
J E Millaud
S Weiss
Oswald H W Siegmund
Anton S Tremsin
John V Vallerga
A Cheng
M Levi
D Aharoni
K Arisaka
F Villa
F Guerrieri
F Panzeri
I Rech
A Gulinatti
F Zappa
M Ghioni
S Cova
University of California, Los Angeles · USPolitecnico di Milano · ITSpace Science Institute · US

Funding

Single-photon counting APD arrays for high-through-put single-molecule assaysR01GM095904 · NIGMS · UNIVERSITY OF CALIFORNIA LOS ANGELES · PI GHIONI, MASSIMO ANTONIO, MICHALET, XAVIER · 2012 to 2016
$2.0M
High-Resolution, High Speed, High-Throughput 3-Dimensional Detector for BiologyR01EB006353 · NIBIB · UNIVERSITY OF CALIFORNIA LOS ANGELES · PI WEISS, SHIMON · 2007 to 2010
$1.6M
Multipixel Hybrid Photon-Counting Detector for High-Throughput Single-Molecule AsR01GM084327 · NIGMS · UNIVERSITY OF CALIFORNIA LOS ANGELES · PI WEISS, SHIMON · 2008 to 2010
$667k
NIBIB NIH HHS R01 EB006353NIBIB NIH HHS R01-EB006353NIGMS NIH HHS R01 GM084327NIGMS NIH HHS R01-GM084327NIGMS NIH HHS R01 GM095904NIGMS NIH HHS R01-GM095904
6 · The paper itself

Abstract

Two optical configurations are commonly used in single-molecule fluorescence microscopy: point-like excitation and detection to study freely diffusing molecules, and wide field illumination and detection to study surface immobilized or slowly diffusing molecules. Both approaches have common features, but also differ in significant aspects. In particular, they use different detectors, which share some requirements but also have major technical differences. Currently, two types of detectors best fulfil the needs of each approach: single-photon-counting avalanche diodes (SPADs) for point-like detection, and electron-multiplying charge-coupled devices (EMCCDs) for wide field detection. However, there is room for improvements in both cases. The first configuration suffers from low throughput owing to the analysis of data from a single location. The second, on the other hand, is limited to relatively low frame rates and loses the benefit of single-photon-counting approaches. During the past few years, new developments in point-like and wide field detectors have started addressing some of these issues. Here, we describe our recent progresses towards increasing the throughput of single-molecule fluorescence spectroscopy in solution using parallel arrays of SPADs. We also discuss our development of large area photon-counting cameras achieving subnanosecond resolution for fluorescence lifetime imaging applications at the single-molecule level.

Indexed as

ElectronsPhotonsComputational BiologyDiffusionEquipment DesignFluorescenceMicroscopy, FluorescenceMolecular ConformationMolecular ImagingSensitivity and SpecificityTime Factors

Identifiers

PMID23267185
PMCPMC3538434
OpenAlexW2117470013

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.