Evaluating the accuracy and large inaccuracy of two continuous glucose monitoring systems.

Lalantha Leelarathna, Marianna Nodale, Janet M Allen, Daniela Elleri, Kavita Kumareswaran, Ahmad Haidar, Karen Caldwell, Malgorzata E Wilinska, Carlo L Acerini, Mark L Evans and 3 more

Abstract readEvaluation StudyMulticenter Study
In one paragraph

Article in Diabetes technology & therapeutics, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed.

  1. Trial
  2. Trial
  3. Trial
  4. Trial
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Future of Automated Insulin Delivery Systems.Diabetes technology & therapeutics · 2017
    Review
  11. Article
  12. Significance and Reliability of MARD for the Accuracy of CGM Systems.Journal of diabetes science and technology · 2017
    Article
  13. Article
  14. Review
  15. Review
  16. Review
  17. Article
  18. Article
  19. Article
  20. Current Trends in Continuous Glucose Monitoring.Journal of diabetes science and technology · 2014
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Lalantha LeelarathnaMetabolic Research Laboratories, Institute of Metabolic Science, Cambridge, UK.
Marianna Nodale
Janet M Allen
Daniela Elleri
Kavita Kumareswaran
Ahmad Haidar
Karen Caldwell
Malgorzata E Wilinska
Carlo L Acerini
Mark L Evans
Helen R Murphy
David B Dunger
Roman Hovorka

Funding

Department of Health CDF-2013-06-035Department of Health PDF/01/036Medical Research Council G0600717
6 · The paper itself

Abstract

objectiveThis study evaluated the accuracy and large inaccuracy of the Freestyle Navigator (FSN) (Abbott Diabetes Care, Alameda, CA) and Dexcom SEVEN PLUS (DSP) (Dexcom, Inc., San Diego, CA) continuous glucose monitoring (CGM) systems during closed-loop studies. RESEARCH DESIGN AND

methodsPaired CGM and plasma glucose values (7,182 data pairs) were collected, every 15-60 min, from 32 adults (36.2±9.3 years) and 20 adolescents (15.3±1.5 years) with type 1 diabetes who participated in closed-loop studies. Levels 1, 2, and 3 of large sensor error with increasing severity were defined according to absolute relative deviation greater than or equal to ±40%, ±50%, and ±60% at a reference glucose level of ≥6 mmol/L or absolute deviation greater than or equal to ±2.4 mmol/L,±3.0 mmol/L, and ±3.6 mmol/L at a reference glucose level of <6 mmol/L.

resultsMedian absolute relative deviation was 9.9% for FSN and 12.6% for DSP. Proportions of data points in Zones A and B of Clarke error grid analysis were similar (96.4% for FSN vs. 97.8% for DSP). Large sensor over-reading, which increases risk of insulin over-delivery and hypoglycemia, occurred two- to threefold more frequently with DSP than FSN (once every 2.5, 4.6, and 10.7 days of FSN use vs. 1.2, 2.0, and 3.7 days of DSP use for Level 1-3 errors, respectively). At levels 2 and 3, large sensor errors lasting 1 h or longer were absent with FSN but persisted with DSP.

conclusionsFSN and DSP differ substantially in the frequency and duration of large inaccuracy despite only modest differences in conventional measures of numerical and clinical accuracy. Further evaluations are required to confirm that FSN is more suitable for integration into closed-loop delivery systems.

Indexed as

AdolescentAdultBlood GlucoseBlood Glucose Self-MonitoringDiabetes Mellitus, Type 1Drug Delivery SystemsEnglandEquipment DesignFemaleHumansHypoglycemic AgentsInsulinInsulin Infusion SystemsMaleReproducibility of ResultsRetrospective StudiesBlood GlucoseHypoglycemic AgentsInsulin

Identifiers

PMID23256605
PMCPMC3558677

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.