Evidence map›Paper›PMID 23256007›Full record

ArticleWideochirurgia i inne techniki maloinwazyjne = Videosurgery and other miniinvasive techniques2012

Own experience improving port implantation in laparoscopic adjustable gastric banding.

Tomasz Szewczyk, Przemysław Janczak, Bogdan Modzelewski

Open access · goldAbstract read
In one paragraph

Article in Wideochirurgia i inne techniki maloinwazyjne = Videosurgery and other miniinvasive techniques, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 83% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Tomasz SzewczykDepartment of Gastroenterological, Oncological and General Surgery, Medical University of Lodz, Poland.
Przemysław Janczak
Bogdan Modzelewski
Medical University of Lodz · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionLaparoscopic adjustable gastric banding (LAGB) is a method frequently used for treating obesity. It requires periodic band regulation associated with the need for port puncture. However, there is always a substantial risk of port rotation.

aimThis publication presents a solution of the problem for a MiniMizer Extra band. MATERIAL AND

methodsOne thousand one hundred and twenty-four individuals were operated on for obesity in the Department of Gastroenterological, Oncological and General Surgery of the Medical University of Lodz between 2005 and 2009. In 637 patients LAGB was performed. These LAGB patients were divided into three groups. In group I (20 patients) MiniMizer Extra bands were placed without port stabilization. In the second group (292 patients) MiniMizer Extra band placement with port stabilization was commenced. In the third group (325 patients) bands of other manufacturers (AMI, Inamed, Midband, Obtech) were used without port stabilization. The port was implanted into the subcutaneous tissue in the left subcostal region, medial to the left working tool trocar position.

resultsPort rotation was observed on the very first band adjustment in 3 (0.92%) and 11 (55%) patients with a band other than MiniMizer Extra (n = 325) and the first 20 patients with a MiniMizer Extra band. A different technique of port stabilization was applied in a further 292 patients on MiniMizer Extra band placement and no port rotation was noted.

conclusionsWe believe that MiniMizer additional port stabilization is necessary for its frequent rotation. Simultaneously, application of our method is easy, does not prolong the procedure significantly and secures comfortable access to the port.

Indexed as

complicationlaparoscopic adjustable gastric bandingport

Identifiers

PMID23256007
PMCPMC3516967
OpenAlexW2143890160

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.