ArticleBMJ case reports2012
Mechanical revascularization of acute iatrogenic anterior cerebral artery occlusions: use of a new coaxial dual-lumen balloon catheter results in rapid access and flow restoration.
Article in BMJ case reports, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Acute iatrogenic occlusion of cerebral vessels is a risk during the performance of neuroendovascular procedures. Most commonly this is a result of thrombus formation within the vessel, thromboembolism or an acute vasospastic response. There are several options for flow restoration including pharmacological, mechanical and microsurgical. Mechanical flow restoration, usually by thrombectomy, is typically performed in large cerebral vessels. Current mechanical thrombectomy devices have limited utility in smaller vessels that are more difficult to access, such as the anterior cerebral artery (ACA). We present two cases where successful flow restoration of an intraoperative acutely occluded or thrombotic ACA was rapidly achieved by balloon dilation using a new coaxial dual-lumen balloon catheter. The time elapsed from the decision to use the balloon catheter until revascularization for each patient was 5 min and 46 s (case 1) and 10 min and 25 s (case 2).
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.