Evidence map›Paper›PMID 23211824›Full record

ArticleInvestigative ophthalmology & visual science2013

The effect of size and species on lens intracellular hydrostatic pressure.

Junyuan Gao, Xiurong Sun, Leon C Moore, Peter R Brink, Thomas W White, Richard T Mathias

Open access · bronzeAbstract readComparative Study
In one paragraph

Article in Investigative ophthalmology & visual science, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 28 papers.

0numbers the graph read from it
0cells of the map it votes in
28citing papers in PubMed
0.8field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

28 citing papers in PubMed, 45 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Junyuan GaoDepartment of Physiology and Biophysics, State University of New York at Stony Brook, Stony Brook, New York 11794-8661, USA.
Xiurong Sun
Leon C Moore
Peter R Brink
Thomas W White
Richard T Mathias
Stony Brook University · US

Funding

Lens Intercellular Communication Connexins and CataractsR01EY013163 · NEI · STATE UNIVERSITY NEW YORK STONY BROOK · PI WHITE, THOMAS W · 2000 to 2019
$6.2M
VOLUME REGULATION IN NORMAL AND CATARACTOUS LENSESR01EY006391 · NEI · STATE UNIVERSITY NEW YORK STONY BROOK · PI MATHIAS, RICHARD T · 1985 to 2014
$5.4M
SiRNA therapeutics: Gap junction delivery in vitro and in vivoR01GM088180 · NIGMS · STATE UNIVERSITY NEW YORK STONY BROOK · PI BRINK, PETER R, COHEN, IRA S · 2010 to 2013
$1.6M
NEI NIH HHS EY06391NEI NIH HHS EY13163NEI NIH HHS R01 EY006391NEI NIH HHS R01 EY013163NIGMS NIH HHS GM088180NIGMS NIH HHS R01 GM088180
6 · The paper itself

Abstract

purposePrevious experiments showed that mouse lenses have an intracellular hydrostatic pressure that varied from 335 mm Hg in central fibers to 0 mm Hg in surface cells. Model calculations predicted that in larger lenses, all else equal, pressure should increase as the lens radius squared. To test this prediction, lenses of different radii from different species were studied.

methodsAll studies were done in intact lenses. Intracellular hydrostatic pressures were measured with a microelectrode-manometer-based system. Membrane conductances were measured by frequency domain impedance analysis. Intracellular Na(+) concentrations were measured by injecting the Na(+)-sensitive dye sodium-binding benzofuran isophthalate.

resultsIntracellular hydrostatic pressures were measured in lenses from mice, rats, rabbits, and dogs with radii (cm) 0.11, 0.22, 0.49, and 0.57, respectively. In each species, pressure varied from 335 ± 6 mm Hg in central fiber cells to 0 mm Hg in surface cells. Further characterization of transport in lenses from mice and rats showed that the density of fiber cell gap junction channels was approximately the same, intracellular Na(+) concentrations varied from 17 mM in central fiber cells to 7 mM in surface cells, and intracellular voltages varied from -45 mV in central fiber cells to -60 mV in surface cells. Fiber cell membrane conductance was a factor of 2.7 times larger in mouse than in rat lenses.

conclusionsIntracellular hydrostatic pressure is an important physiological parameter that is regulated in lenses from these different species. The most likely mechanism of regulation is to reduce the density of open Na(+)-leak channels in fiber cells of larger lenses.

Indexed as

Models, BiologicalAnimalsBenzofuransDogsElectric ImpedanceEthers, CyclicFluorescent DyesGap JunctionsHydrostatic PressureLens, CrystallineManometryMembrane PotentialsMiceOrgan SizeRabbitsRatsBenzofuransEthers, CyclicFluorescent DyesSodiumsodium-binding benzofuran isophthalateWater

Identifiers

PMID23211824
PMCPMC3544420
OpenAlexW1983178795

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.