Trial reportDiabetes care2013
Closed-loop basal insulin delivery over 36 hours in adolescents with type 1 diabetes: randomized clinical trial.
Trial report in Diabetes care, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02657083 (Prevention of Hypoglycemia After Exercise Using DreaMed Substance Administration Device in Children and Adolescents With Type 1 Diabetes), which is not on this map. Cited by 58 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Prevention of Hypoglycemia After Exercise Using DreaMed Substance Administration Device in Children and Adolescents With Type 1 Diabetes (The PHYSI-DREAM Study)
Who cites it
58 citing papers in PubMed, 1 synthesis or guideline pooled it, 157 citations in OpenAlex.
- Pooled it
- Closed-loop glucose control in young people with type 1 diabetes during and after unannounced physical activity: a randomised controlled crossover trial.Diabetologia · 2017Trial
- Manual Closed-Loop Insulin Delivery Using a Saddle Point Model Predictive Control Algorithm: Results of a Crossover Randomized Overnight Study.Journal of diabetes science and technology · 2017Trial
- Predictive Hyperglycemia and Hypoglycemia Minimization: In-Home Evaluation of Safety, Feasibility, and Efficacy in Overnight Glucose Control in Type 1 Diabetes.Diabetes care · 2017Trial
- Trial
- Home Use of Day-and-Night Hybrid Closed-Loop Insulin Delivery in Suboptimally Controlled Adolescents With Type 1 Diabetes: A 3-Week, Free-Living, Randomized Crossover Trial.Diabetes care · 2016Trial
- Safety, efficacy and glucose turnover of reduced prandial boluses during closed-loop therapy in adolescents with type 1 diabetes: a randomized clinical trial.Diabetes, obesity & metabolism · 2015Trial
- Modelling endogenous insulin concentration in type 2 diabetes during closed-loop insulin delivery.Biomedical engineering online · 2015Trial
- Safety of closed-loop therapy during reduction or omission of meal boluses in adolescents with type 1 diabetes: a randomized clinical trial.Diabetes, obesity & metabolism · 2014Trial
- Preliminary evaluation of a new semi-closed-loop insulin therapy system over the prandial period in adult patients with type 1 diabetes: the WP6.0 Diabeloop study.Journal of diabetes science and technology · 2014Trial
- Trial
- Overnight glucose control with an automated, unified safety system in children and adolescents with type 1 diabetes at diabetes camp.Diabetes care · 2014Trial
- Adding heart rate signal to a control-to-range artificial pancreas system improves the protection against hypoglycemia during exercise in type 1 diabetes.Diabetes technology & therapeutics · 2014Trial
- Outpatient glycemic control with a bionic pancreas in type 1 diabetes.The New England journal of medicine · 2014Trial
- An integrated multivariable artificial pancreas control system.Journal of diabetes science and technology · 2014Trial
- Autonomous and continuous adaptation of a bihormonal bionic pancreas in adults and adolescents with type 1 diabetes.The Journal of clinical endocrinology and metabolism · 2014Trial
- Artificial pancreas using a personalized rule-based controller achieves overnight normoglycemia in patients with type 1 diabetes.Diabetes technology & therapeutics · 2014Trial
- Overnight closed-loop insulin delivery in young people with type 1 diabetes: a free-living, randomized clinical trial.Diabetes care · 2014Trial
- Early Stages of Automated Insulin Delivery.Journal of diabetes science and technology · 2025Review
- Early Stages of Automated Insulin Delivery.Diabetes technology & therapeutics · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors at 2 institutions in 2 countries.
Funding
Abstract
objectiveWe evaluated the safety and efficacy of closed-loop basal insulin delivery during sleep and after regular meals and unannounced periods of exercise. RESEARCH DESIGN AND
methodsTwelve adolescents with type 1 diabetes (five males; mean age 15.0 [SD 1.4] years; HbA1c 7.9 [0.7]%; BMI 21.4 [2.6] kg/m(2)) were studied at a clinical research facility on two occasions and received, in random order, either closed-loop basal insulin delivery or conventional pump therapy for 36 h. During closed-loop insulin delivery, pump basal rates were adjusted every 15 min according to a model predictive control algorithm informed by subcutaneous sensor glucose levels. During control visits, subjects' standard infusion rates were applied. Prandial insulin boluses were given before main meals (50-80 g carbohydrates) but not before snacks (15-30 g carbohydrates). Subjects undertook moderate-intensity exercise, not announced to the algorithm, on a stationary bicycle at a 140 bpm heart rate in the morning (40 min) and afternoon (20 min). Primary outcome was time when plasma glucose was in the target range (71-180 mg/dL).
resultsClosed-loop basal insulin delivery increased percentage time when glucose was in the target range (median 84% [interquartile range 78-88%] vs. 49% [26-79%], P = 0.02) and reduced mean plasma glucose levels (128 [19] vs. 165 [55] mg/dL, P = 0.02). Plasma glucose levels were in the target range 100% of the time on 17 of 24 nights during closed-loop insulin delivery. Hypoglycemia occurred on 10 occasions during control visits and 9 occasions during closed-loop delivery (5 episodes were exercise related, and 4 occurred within 2.5 h of prandial bolus).
conclusionsDay-and-night closed-loop basal insulin delivery can improve glucose control in adolescents. However, unannounced moderate-intensity exercise and excessive prandial boluses pose challenges to hypoglycemia-free closed-loop basal insulin delivery.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.