ArticlePloS one2012
Detailing radio frequency heating induced by coronary stents: a 7.0 Tesla magnetic resonance study.
Article in PloS one, 2012. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 47 citations in OpenAlex.
- Assessment of MR-Induced Heating Effects in Four Common Veterinary Implants at 1.5 and 3.0 T: A Phantom Study.Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association · 2026Article
- Straightforward Magnetic Resonance Temperature Measurements Combined with High Frame Rate and Magnetic Susceptibility Correction.Bioengineering (Basel, Switzerland) · 2023Article
- Computational modeling of the thermal effects of flow on radio frequency-induced heating of peripheral vascular stents during MRI.Biomedical physics & engineering express · 2023Article
- MRI of Implantation Sites Using Parallel Transmission of an Optimized Radiofrequency Excitation Vector.Tomography (Ann Arbor, Mich.) · 2023Article
- Ultra-high field cardiac MRI in large animals and humans for translational cardiovascular research.Frontiers in cardiovascular medicine · 2023Article
- 7T MR Safety.Journal of magnetic resonance imaging : JMRI · 2021Article
- [Safety of implants in high field and ultrahigh field MRI].Der Radiologe · 2019Review
- Risk assessment of copper-containing contraceptives: the impact for women with implanted intrauterine devices during clinical MRI and CT examinations.European radiology · 2019Article
- Radio-Frequency Safety Assessment of Stents in Blood Vessels During Magnetic Resonance Imaging.Frontiers in physiology · 2018Article
- Open Source 3D Multipurpose Measurement System with Submillimetre Fidelity and First Application in Magnetic Resonance.Scientific reports · 2017Article
- Article
- Experience with magnetic resonance imaging of human subjects with passive implants and tattoos at 7 T: a retrospective study.Magma (New York, N.Y.) · 2015Article
- Thermal magnetic resonance: physics considerations and electromagnetic field simulations up to 23.5 Tesla (1GHz).Radiation oncology (London, England) · 2015Article
- [Cardiovascular ultrahigh field magnetic resonance imaging : challenges, technical solutions and opportunities].Der Radiologe · 2013Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The sensitivity gain of ultrahigh field Magnetic Resonance (UHF-MR) holds the promise to enhance spatial and temporal resolution. Such improvements could be beneficial for cardiovascular MR. However, intracoronary stents used for treatment of coronary artery disease are currently considered to be contra-indications for UHF-MR. The antenna effect induced by a stent together with RF wavelength shortening could increase local radiofrequency (RF) power deposition at 7.0 T and bears the potential to induce local heating, which might cause tissue damage. Realizing these constraints, this work examines RF heating effects of stents using electro-magnetic field (EMF) simulations and phantoms with properties that mimic myocardium. For this purpose, RF power deposition that exceeds the clinical limits was induced by a dedicated birdcage coil. Fiber optic probes and MR thermometry were applied for temperature monitoring using agarose phantoms containing copper tubes or coronary stents. The results demonstrate an agreement between RF heating induced temperature changes derived from EMF simulations versus MR thermometry. The birdcage coil tailored for RF heating was capable of irradiating power exceeding the specific-absorption rate (SAR) limits defined by the IEC guidelines by a factor of three. This setup afforded RF induced temperature changes up to +27 K in a reference phantom. The maximum extra temperature increase, induced by a copper tube or a coronary stent was less than 3 K. The coronary stents examined showed an RF heating behavior similar to a copper tube. Our results suggest that, if IEC guidelines for local/global SAR are followed, the extra RF heating induced in myocardial tissue by stents may not be significant versus the baseline heating induced by the energy deposited by a tailored cardiac transmit RF coil at 7.0 T, and may be smaller if not insignificant than the extra RF heating observed under the circumstances used in this study.